5.3 Flange Focal Distance
12
±0,2
5
6. Installation
Lens mounting
Notice
Avoid contamination of the sensor and the lens by dust and airborne particles when
mounting the support or the lens to the device!
Therefore the following points are very important:
▪
Install the camera in an environment that is as dust free as possible!
▪ Keep the dust cover (foil) on camera as long as possible!
▪
Hold the print with the sensor downwards with unprotected sensor.
▪
Avoid contact with any optical surface of the camera!
6.1 Environmental Requirements
Temperature
Storage temperature
-10 °C ... +70 °C ( +14 °F ... +158 °F)
Operating temperature*
see Heat Transmission
* If the environmental temperature exceeds the values listed in the table below, the cam
-
era must be cooled. (see Heat Transmission)
Humidity
Storage and Operating Humidity
10 % ... 90 %
Non-condensing