4

The device must be operated in accordance with the stipulations of the installation and 

operating instructions. The relevant laws, regulations and standards for the planned 

application must be observed.

2

 

Operation in potentially explosive environments  

 

The device complies with the 

EU standard

 2014/34/EU for potentionally explosive atmospheres. 

It can be used in accordance with 

equipment categories 3 G

 (explosive gas atmosphere) and 

3 D 

(explosive dust atmosphere)

 

 

Equipment category 3 G:

  - Ex labeling: 

 

II 3 G Ex nA IIC T4 Gc

 

 

 

 

- Conforms to standard: 

EN 60079-0:2012 + A11:2013 

      EN 

60079-15:2010 

 

 

 

- Type of protection:  

nA 

 

 

 

- Temperature class: 

T4 

 

 

 

- Group of equipment: 

II 

Equipment category 3 D:

  - Ex labeling: 

 

II 3 D Ex tc IIIC T135°C Dc

 

 

 

 

- Conforms to standard: 

EN 60079-31: 2014 

 

 

 

- Protective principle: 

Protection by enclosure 

 

 

 

- Max. surface temperature:  +135 °C 

 

 

 

- Group of equipment: 

III

 

The operation in other explosive atmospheres is 

not

 permissible.

2.1

 

In Ex areas the device must only be used within the 

ambient temperature

 range from -20 °C to 

+40 °C.

2.2

 

The plant operator must ensure that any possible 

dust deposit

 does not exceed a thickness of 

5 mm (in accordance with EN 60079-14).

2.3

 An 

UL listing

 that may be stated elsewhere is 

not valid for use in explosive environ- 

ments

.

2.4

 

Operation of the device is only permissible when ...

 

the details on the type label of the device match the on-site conditions for the permissible 

Ex area in use (group of equipment, equipment category, zone, temperature class or maxi-

mum surface temperature),

 

the details on the type label of the device match the electrical supply network,

 

the device is undamaged (no damage resulting from transport or storage), and

 

it has been checked that there is no explosive atmosphere, oils, acids, gases, vapors, 

radiation etc. present during installation.

2.5

 

It is not permissible to make any alteration to equipment that is used in potentially explosive envi-

ronments. Repairs may only be carried out by authorized authorities provided by the manufacturer. 

Contravention invalidates the EX approval.

2.6 

Attend the norm EN 60079-14 during mount and operation.

 

 Operation in potentially explosive environments 

2

Summary of Contents for HUBNER BERLIN HMG 111

Page 1: ...MB157 11055770 Baumer_HMG111_II_DE EN 16A4 HMG 111 Absoluter Drehgeber Absolute Encoder Montage und Betriebsanleitung Installation and operating instructions...

Page 2: ...momentst tze 12 5 5 Hinweis zur Vermeidung von Messfehlern 13 5 6 Schritt 5 14 5 7 Schritt 6 14 5 8 Schritt 7 15 5 9 Schritt 8 15 5 10 Schritt 9 16 5 11 Schritt 10 16 5 12 Anbauhinweis 17 6 Abmessung...

Page 3: ...Torque arm 12 5 5 How to prevent measurement errors 13 5 6 Step 5 14 5 7 Step 6 14 5 8 Step 7 15 5 9 Step 8 15 5 10 Step 9 16 5 11 Step 10 16 5 12 Mounting instruction 17 6 Dimension 17 7 Electrical...

Page 4: ...Lagertemperaturbereich des Ger tes liegt zwischen 15 C bis 70 C 1 5 Der Betriebstemperaturbereich des Ger tes liegt zwischen 20 C bis 85 C eingeschr nkt im Ex Bereich siehe Abschnitt 2 am Geh use geme...

Page 5: ...5 The operating temperature range of the device is between 20 C and 85 C restricted in potentially explosive environments see section 2 measured at the housing 1 6 EU Declaration of Conformity meetin...

Page 6: ...s im Ex Bereich betr gt 20 C bis 40 C 2 2 Der Anlagenbetreiber hat zu gew hrleisten dass eine m gliche Staubablagerung eine maxi male Schichtdicke von 5 mm nicht berschreitet gem EN 60079 14 2 3 Eine...

Page 7: ...st only be used within the ambient temperature range from 20 C to 40 C 2 2 The plant operator must ensure that any possible dust deposit does not exceed a thickness of 5 mm in accordance with EN 60079...

Page 8: ...nkel unbedingt einhalten 3 4 Zerst rungsgefahr durch mechanischen Schock Starke Ersch tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemals Gewalt anwenden Bei sachgem er Mont...

Page 9: ...clearances and or angles are observed 3 4 Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the optical sensing system Never use forc...

Page 10: ...um Anschluss an 15 15 Stecker D SUB 15 polig am Drehgebergeh use 1 Housing 2 Blind hollow shaft with spanner flat 17 a f 3 Support plate for torque arm 4 Hexagon screw M6x18 mm ISO 4017 A2 10 mm a f 5...

Page 11: ...Erdungsband 18e Scheibe B6 4 ISO 7090 Ms f r Erdungsband 19 Montage Demontageset als Zubeh r erh ltlich Bestellnummer 11077087 bestehend aus 19a Federring 6 DIN 7980 19b Zylinderschraube M6x30 ISO 476...

Page 12: ...unting kit available as accessory order number 11077087 including 19c Setscrew M6x10 ISO 7436 5 8 Vzk 19d Cylinder screw M8x45 ISO 4762 A2 4 3 Zur Demontage erforderlich nicht im Lieferumfang enthalte...

Page 13: ...157 11055770 Baumer_HMG111_II_DE EN 16A4 10 Montage Mounting 5 5 Montage 5 1 Schritt 1 5 Mounting 5 1 Step 1 5 2 Schritt 2 5 2 Step 2 10 mm 10 mm 6 5 16 4 3 8 9 3 mm Siehe Seite 7 oder 8 See page 7 or...

Page 14: ...itt 5 5 Au erdem verursachen Rundlauffeh ler Vibrationen die die Lebensdauer des Drehgebers verk rzen k nnen The drive shaft should have as less runout as possible because this can otherwise result in...

Page 15: ...sollte spielfrei erfolgen Ein Spiel von beispiels weise 0 03 mm entspricht einem Rund lauffehler des Drehgebers von 0 06 mm was zu einem gro en Winkelfehler f hren kann siehe Abschnitt 5 5 The torque...

Page 16: ...es tigungsbleche f r die St tzen erh ltlich 2 wenn L2 L1 muss mit der L nge L2 gerechnet werden Weitere Informationen erhalten Sie unter der Telefon Hotline 49 0 30 69003 111 i 5 5 How to prevent meas...

Page 17: ...mer_HMG111_II_DE EN 16A4 14 Montage Mounting 5 Zul Anzugsmoment Max tightening torque Mt 6 Nm 5 6 Schritt 5 5 6 Step 5 5 7 Schritt 6 5 7 Step 6 Siehe Seite 7 oder 8 See page 7 or 8 18d 18e 7 1 6x8 mm...

Page 18: ...ehe Abschnitt 7 2 View X see section 7 2 Zweites Kabel optional Second cable optionally 22 mm 10 8 11 12 TX 10 13 17 5 13 mm Zur Gew hrleistung der angegebenen Schutzart sind nur geeignete Kabel durch...

Page 19: ...Schritt 9 5 10 Step 9 5 11 Schritt 10 5 11 Step 10 TX 10 8 12 Vor der Montage des Klemmenka stendeckels pr fen ob der O Ring unbesch digt ist Check that the o ring of the terminal box is not damaged b...

Page 20: ...Abmessung Mounting Dimension 6 Abmessung 74315 6 Dimension 74315 All dimensions in millimeters unless otherwise stated Drehrichtung positiv Positive rotating direction 5 12 Anbauhinweis 5 12 Mounting...

Page 21: ...channel 1 K1 A A Ausgangssignal Kanal 1 invertiert Output signal channel 1 inverted K2 B B Ausgangssignal Kanal 2 90 versetzt zu Kanal 1 Output signal channel 2 offset by 90 to channel 1 K2 B B Ausgan...

Page 22: ...cremental line drivers Aderendh lsen benutzen Use core end ferrules Rot Red UB Wei White K1 Braun Brown K1 Gr n Green K2 Grau Grey Clock Rosa Pink Clock Gelb Yellow K2 Kabelschirm Cable shield Blau Bl...

Page 23: ...055770 Baumer_HMG111_II_DE EN 16A4 20 Demontage Dismounting 8 8 2 Schritt 2 8 2 Step 2 8 Demontage 8 1 Schritt 1 8 Dismounting 8 1 Step 1 15 9 8 14 3 mm 13 17 22 mm TX 10 Siehe Seite 7 oder 8 See page...

Page 24: ...er_HMG111_II_DE EN 16A4 MB157 11055770 8 Demontage Dismounting 8 4 Schritt 4 8 4 Step 4 8 3 Schritt 3 8 3 Step 3 18d 1 6x8 mm 18e 18a 16 18b 18c 10 mm Siehe Seite 7 oder 8 See page 7 or 8 7 17 mm 5 mm...

Page 25: ...MB157 11055770 Baumer_HMG111_II_DE EN 16A4 22 Demontage Dismounting 8 8 5 Schritt 5 8 5 Step 5 8 6 Schritt 6 8 6 Step 6 8 7 Schritt 7 8 7 Step 7 Siehe Seite 9 See page 9 19c 19d 17 mm 6 mm...

Page 26: ...3 2007 A1 2011 Diagnosefunktion Regelbereich LED Strom verlassen Einschrittigkeitsfehler Zulassungen CE UL Zulassung E256710 9 2 Technische Daten mechanisch Baugr e Flansch 105 mm Wellenart 16 mm ein...

Page 27: ...A1 2011 Diagnostic function Adjust range LED current left Code consistency error Approvals CE UL approval E256710 9 2 Technical data mechanical design Size flange 105 mm Shaft type 16 mm blind hollow...

Page 28: ...ic links HEAG 172 HEAG 174 und HEAG 176 Digital speed switch DS 93 Analyzer for encoders HENQ 1100 10 Zubeh r Drehmomentst tze Gr e M6 Bestellnummer s Abschnitt 4 7 Montageset f r Drehmoment st tze Gr...

Page 29: ...2011 Standard s EN 60079 0 2012 A11 2013 EN 60079 15 2010 EN 60079 31 2014 Norme s EN 50581 2012 Ort und Datum Berlin 15 08 2016 Unterschrift Name Funktion Daniel Kleiner Place and date Signature nam...

Page 30: ...Baumer_HMG111_II_DE EN 16A4 MB157 11055770...

Page 31: ...MB157 11055770 Baumer_HMG111_II_DE EN 16A4...

Page 32: ...H P O Box 12 69 43 10609 Berlin Germany Phone 49 0 30 69003 0 Fax 49 0 30 69003 104 info baumerhuebner com www baumer com motion Originalsprache der Anleitung ist Deutsch Technische nderungen vorbehal...

Reviews: