Ausgangssignale / Output signals
32
Baumer_HS35_II_DE-EN_1706.indd
10.6
Output signals HS35S
Clockwise rotation when looking at the
mounting side.
10.6
Ausgangssignale HS35S
Drehrichtung im Uhrzeigersinn bei Blick
auf die Anbauseite.
360° el.
90° el.
2.5 V
1
V
1
V
0.4 V
2.5 V
2.5 V
SS
SS
Differenzsignale
A = A+ & A-
B = B+ & B-
Z = Z+ & Z-
360° el.
90° el.
2.5 V
1
V
1
V
0.4 V
2.5 V
2.5 V
SS
SS
differential signals
A = A+ & A-
B = B+ & B-
Z = Z+ & Z-