25
Baumer_TDP02-OG9-TDPZ02-OG9_II_DE-EN (14A1)
MB079.3 - 11130053
11
Technical data
11
Technical data
11.1
Technical data - electrical ratings
•
Interference immunity:
EN 61000-6-2:2005
•
Emitted interference:
EN 61000-6-3:2007/A1:2011
•
Approvals:
CE, RoHS
11.2
Technical data - electrical ratings (tachogenerator)
•
Reversal tolerance:
≤0.1%
•
Linearity tolerance:
≤0.15%
•
Temperature coefficient:
±0.05%/K
•
Isolation class:
B
•
Calibration tolerance:
±1 %
•
Climatic test:
Humid heat, constant (IEC 60068-2-3, Ca)
TDP 0,2 + OG 9
•
Performance:
12 W (speed >3000 rpm)
•
Armature-circuit time-constant (
τ
A
):
<
75 µs
•
Open-circuit voltage:
10...150 mV per rpm
TDPZ 0,2 + OG 9
•
Performance:
2x 3 W (speed >3000 rpm)
•
Armature-circuit time-constant (
τ
A
):
<
40 µs
•
Open-circuit voltage:
20...100 mV per rpm
11.3
Technical data - electrical ratings (encoder)
•
Voltage supply:
5 VDC ±5 % / 9...26 VDC
9...30 VDC
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
1...1250
•
Phase shift:
90° ±20°
•
Scan ratio:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz
•
Output signals:
K1, K2, K0 + inverted
•
Output stages:
TTL/RS422 / HTL-P (power linedriver)
11.4
Technical data - mechanical design
•
Dimensions (flange):
ø115 mm
•
Shaft type:
ø11 mm solid shaft (Option: ø14 mm solid shaft)
•
Shaft loading:
≤60 N axial, ≤80 N radial
•
Flange:
EURO flange B10
•
Protection DIN EN 60529:
IP 55 (Option: IP 56)
•
Speed (n):
≤10000 rpm
•
Torque:
1.5 Ncm
•
Materials:
Housing: aluminium die-cast, Shaft: stainless steel
•
Operating temperature:
-30...+100°C
•
Resistance:
IEC 60068-2-6:2007:
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008:
Shock 100 g, 6 ms
•
Connection:
2x terminal box