![Baumer 11205779 Operating Manual Download Page 20](http://html.mh-extra.com/html/baumer/11205779/11205779_operating-manual_2710696020.webp)
Manual R600V.DAH5 (EN)
Page 20 of 32
R600V.DAH5_manual_1.5 (EN).docm
Tab 9
Target Distance Message (main message)
Start bit
Bits
Offset
Scaling
Description
1
2
0
1
Sensor status
0 = No error
1 = Reversible error. (e.g. temperature too high)
2 = Irreversible error. Sensor measurement not available
9
8
0
1%
Target confidence*/**
Value 0…100% (higher confidence = detection of target
better)
17
24
0
0.1mm
Target distance **
49
16
32768
1mm/sec
Target speed (positive: increasing distance)
*Target confidence is a function of signal strength. Above certain signal amplitude, confi-
dence will always be 100%
**Target confidence and target distance will be
“0” if no target is detected