- 8 -
POWER
(kW)
BURNER
TYPE
GAS TYPE
PRESSURE
(mbar)
INJECTOR
MARKING
(1/100 mm)
GAS
CON-
SUMPTION* MAX. MIN.
liquid gas
G30/G31
28..30/37
62
145 g/h
OVEN
(dm
3
37)
FP 96-16 2 ovens
(small oven)
natural gas
G20
20
108
190 dm
3
/h
2.000 0.700
liquid gas
G30/G31
28..30/37
79
193 g/h
OVEN
(dm
3
47/67)
55-65-75-66
P85-P96
FG 96-16 2 ovens
(medium-size oven)
natural gas
G20
20
122
252 dm
3
/h
2.650 1.000
liquid gas
G30/G31
28..30/37
93
276 g/h
OVEN
(dm
3
80/105)
85-86 (large oven)
natural gas
G20
20
140
362 dm
3
/h
3.800 1.000
liquid gas
G30/G31
28..30/37
98
305 g/h
OVEN
(dm
3
111/123)
96-16 (giant oven)
natural gas
G20
20
150
400 dm
3
/h
4.200 1.000
liquid gas
G30/G31
28..30/37
60
116 g/h
GRILL
(dm
3
37)
FP 96-16 2 ovens
(small oven)
natural gas
G20
20
101
152 dm
3
/h
1.600
liquid gas
G30/G31
28..30/37
65
145 g/h
GRILL
(dm
3
47/67)
55-65-75-66
P85-P96
FG 96-16 2 ovens
(medium-size oven)
natural gas
G20
20
108
190 dm
3
/h
2.000
liquid gas
G30/G31
28..30/37
88
240 g/h
GRILL
(dm
3
80/123)
85-86-96-16
(large oven and giant
oven)
natural gas
G20
20
136
314 dm
3
/h
3.300
* In reference conditions, gas temperature 15°C, atmospheric pressure 1013.25 mbar