8
pipe and the cooktop.
Important: when the installation is complete:
check that all couplings are completely sealed by using a soapy solution. Never use
a flame.
ensure that the flexible pipe cannot come into contact with any moving part of the
cook top (e.g. drawer) and that it is not in a position where it could be damaged.
check the burners for correct operation. The flames must be clearly visible, and
should be blue and green at the center. If the flame is unstable, increase the
minimum power.
Adaptation to a
different type of gas
The procedure or adaptation of the cooker to another type of gas does not require removal
of the appliance from the worktop.
Before adapting, disconnect the appliance from the power mains and close the gas supply
valve.
Remove the support grid and burner covers with respective crowns.
Replace the existing nozzles for nominal thermal load with corresponding nozzles for the
new gas type and supplied provided (see table below). In double burners, adjustment
elements are accessible behind the main nozzle protective plate.
After finishing this sequence, replace the old setting label with the new one provided for
the new injectors.
The category with the related types of gas can be used are included in Table “Adaptation
to a different type of gas”.
Minimum flow
adjustment
Instructions for urban (G110, G120, G150.1) and methane gas (G20, G25)
1. Light the burner and bring it to the minimum position.
2. Remove the control knobs, including the gaskets.
3. Remove the gas tap knob and turn the adjustment screw on the side of the tap rod until a
regular minimum flame is obtained:
anti-clockwise to increase the gas flow
clockwise to reduce the gas flow
4. Re-assemble the knob and verify burner flame stability (when quickly rotating the hand
from maximum to minimum position the flame must not shut off).
5. Repeat the operation on all gas taps.
Instructions for liquid gas (LPG: G30, G31)
Tighten the screw on the side of the tap, rod clockwise completely.
TECHNICAL INFORMATION
BMEH3GSS
BMEH381G
BMEH6GSS BMEH9GSS BMEH9GBLSS
A
: Auxiliary
SR
: Semirapid
R
: Rapid
MW
: Mini-Wok
DC4M
: Dual Crown
DC5D
: Dual Crown
Operating voltage
220-240 V~ ; 50/60 Hz
Regulated for gas
G30 = 30mbar
G30 = 30mbar
G30 = 30mbar
G30 = 30mbar
G30 = 30mbar
Qn
TOT
4000 W
5000 W
7800 W
11500 W
12500 W
BMEH6GBLSS
A
: Auxiliary
SR
: Semirapid
R
: Rapid
MW
: Mini-Wok
DC4M
: Dual Crown
DC5D
: Dual Crown
Operating voltage
220-240 V~ ; 50/60 Hz
Regulated for gas
G30 = 30mbar
Qn
TOT
8500 W