o
Do not use the induction hob in narrow spaces to avoid hindering
the release of heat through the ventilation gaps.
o
Do not place the appliance onto carpet, a tablecloth or paper to
avoid blocking the air vents which can result in overheating.
o
The appliance should not be located near any other heat source
such as radiators, heaters, cookers, ovens and hobs.
Electrical connection
Before connecting the appliance, make sure that the supply voltage
marked on the rating plate corresponds with your mains supply
voltage.
WARNING: THIS APPLIANCE MUST BE EARTHED.
o
This appliance should be wired into a 13 A double pole
switched fused spur outlet, having 3 mm contact
separation and placed in an easily accessible position
adjacent to the appliance. The spur outlet must still be
accessible even when your hob is located in its housing.
o
If you have to change the hob power cord, the earthing
(yellow/green) conductor must always be 10 mm longer than the
line conductors.
o
Care must be taken to ensure that the temperature of the mains
supply cable does not exceed 50°C.
o
If the mains supply cable is damaged, then it must be replaced
by an appropriate replacement.
o
Cable type: H05 RRF 3 core x 1.5 mm²