19
o
Conversion for use on LPG and other gases must only be
undertaken by a qualified person. For information on the use of
other gases, please contact the Baumatic Advice Line.
o
The hob must be installed by a qualified person, in accordance
with the current edition of the Gas Safety (Installation and Use)
(Amendment) Regulations and the relevant building/I.E.E.
Regulations.
o
Failure to install the appliance correctly could invalidate
Baumatic’s guarantee and lead to prosecution under the
regulations quoted above.
o
In the UK,
GASSAFE
registered installers are authorised to
undertake the installation and service work, in compliance with
the above regulations.
Ventilation requirements
o
The room containing the hob should have an air supply in
accordance with the current edition of BS 5440: Part 2:
o
The room must have opening windows or equivalent; some
rooms may also require a permanent vent.
o
If the room has a volume between 5 and 10m³, it will require an
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.
o
If the room has a volume of less than 5m³, it will require an air
vent of 100cm² (effective area).
o
If it is installed in a room with a volume that exceeds 11m³, then
no air vent is required.
o
If there are any other fuel burning appliances in the same room
the current edition of BS 5440: Part 2: should be consulted to
determine air vent requirements.
o
Ensure that the room containing the hob is well ventilated, keep
natural ventilation holes or install a mechanical ventilation device
(mechanical cooker hood).
o
Prolonged intensive use of the appliance may call for additional
ventilation, either by the opening of a window, or by increasing
the level of the mechanical ventilation device (where present).
Summary of Contents for BHG640SS
Page 1: ...el 1 BHG640SS 60 cm BHG740SS 70 cm Gas on glass hobs ...
Page 27: ...27 ...
Page 28: ...28 28 ...