o
Put the gas seal into the elbow.
o
Fully tighten the elbow and seal onto the gas rail.
o
The elbow
MUST
be pointing in a downwards direction.
o
Gas pressure may be checked on a semi-rapid hob burner.
Remove the appropriate injector and attach a test nipple. Light
the other burners and observe that the gas pressure complies
with the gas standards in force.
o
IMPORTANT: On completion carry out a gas soundness
test.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o
Switch the burner on
and set the knob at the
minimum position.
o
Remove the knob from
the tap and place a
small bladed
screwdriver in the
centre of the tap shaft.
19