o
Place the clamp
(B)
over the holes that match the size of the
screws. There are one set of screw holes in each corner of the
hob. Slightly tighten a screw
(C)
through the clamp
(B)
so that
the clamp is attached to the hob, but so that you can still adjust
the position of it.
o
Carefully turn the hob back over and then gently lower it into the
aperture hole that you have cut out.
o
On the underneath of the hob, adjust the clamps into a position
that is suitable for your worktop. Then fully tighten the screws
(C)
to secure the hob into position.
Gas connection
17
nts.
This appliance must be installed by a competent
person in accordance with the current versions of
the following UK (United Kingdom) or ROI (Republic
of Ireland) Regulations and Safety Standards or
their European Norm Replaceme
Important information
o
This oven is supplied to run on
LPG only
and cannot be used on
any other type of gas without modification.
o
The hob must be installed by a qualified person, in accordance
with the current edition of the Gas Safety (Installation and Use)
Regulations and the relevant building/I.E.E. Regulations.
o
Failure to install the appliance correctly could invalidate
Baumatic’s guarantee and lead to prosecution under the
regulations quoted above.
o
In the UK,
GASSAFE
registered installers are authorised to
undertake the installation and service work, in compliance with
the above regulations.
Ventilation requirements
o
The room containing the hob should have an air supply in
accordance with the current edition of BS 5440: Part 2:
o
The room must have opening windows or equivalent; some
rooms may also require a permanent vent.
o
If the room has a volume between 5 and 10m³, it will require an
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.