5) GAS CONNECTION

The gas connection is located in the rear and on the

underside of the appliance 100 mm from the right

hand side.

A. 

The hotplate can be connected with rigid pipe as

specified in AS5601 table 3.1.

B. 

If installing with a hose assembly, install with a

hose assembly that complies with AS/ANZ 1869

(AGA Approved), 10mm ID, class B or D, no more

than 1.2m long and in accordance with AS5601.

Ensure that the hose does not contact the hot

surfaces of the hotplate, oven, dishwasher or any

other appliance that may be installed underneath or

next to the hotplate. The hose should not be

subjected to abrasion, kinking or permanent

deformation and should be able to be inspected

along its entire length with the cooktop in the

installed position.

Unions compatible with the hose fittings must be

used and all connections tested for gas leaks.

Natural Gas

Natural Gas installations require the connection of

a gas regulator at the appliance. 

Assemble the regulator (noting the gas flow

direction) and transition pieces (supplied with the

appliance), in accordance with figure 12.

The transition piece on the supply side of the

regulator must be provided by the installer.

Liquified Petroleum Gas

In a LPG installation the gas regulation is made at

the gas cylinder and regulation at the appliance is

not required. To connect supply to the appliance

use transition pieces as shown in figure 12. These

pieces  are  supplied  with  the  appliance  on

purchase.

WARNING:

THE BURNER FLAME MUST BE ADJUSTED BY

THE INSTALLER.

FAULTY  INSTALLATION  WILL  NOT  BE

COVERED UNDER WARRANTY.

THE  APPLIANCE  IS  FACTORY  SET  FOR

NATURAL GAS. THE TEST POINT PRESSURE

SHOULD BE ADJUSTED TO 1.00kPa WITH THE

WOK BURNER OPERATING AT MAXIMUM.

INSTALLATION

FIG. 11

FIG. 12

IMPORTANT: 

a  perfect  installation,  adjustment  or

transformation of the cook top to use other

gases requires a QUALIFIED INSTALLER: a

failure  to  follow  this  rule  will  void  the

warranty.

Summary of Contents for BGH60

Page 1: ...Instructions for the installation and advice for the maintenance MODEL BGH60 Instructions Manual MODEL BGH60 PLEASE READ THIS MANUAL BEFORE INSTALLING THE HOTPLATE COD 01099HS 31 07 2012...

Page 2: ...set and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and ca...

Page 3: ...trol knob left 15 Electric ignition button 16 Ultra rapid gas burner Wok 14 5 MJ 11 4 MJ 17 Trivet for ultra rapid burner 18 Burner 16 control knob Attention this appliance has been manufactured for d...

Page 4: ...n in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 MJ 22 24 Rapid 12 0 MJ 10 4 MJ 20 22 Semi rapid 7 1 MJ 6 2 MJ 16 18 Auxiliary 4 1 MJ 3 5 MJ 10 14 WARNINGS Burners with flame failure device may o...

Page 5: ...en who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage resulting fro...

Page 6: ...towards the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop C...

Page 7: ...nts given for the hole into which the appliance will be recessed see fig 8 Any adjoining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible material...

Page 8: ...s Natural Gas installations require the connection of a gas regulator at the appliance Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accorda...

Page 9: ...the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspond...

Page 10: ...appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all gas they are male conical type Re...

Page 11: ...the Only for use with U LPG label adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models BGH60 1...

Page 12: ...on on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or...

Page 13: ...p is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove the ta...

Page 14: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Page 15: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Page 16: ...16 0 1 2 3 4...

Reviews: