background image

5

USE

Notes:

Use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The

room must therefore be well ventilated by keeping the natural air vents clear (fig. 3) and by

activating the mechanical aeration device (suction hood or electric fan fig. 4 and fig. 5).

Intensive and lengthy use of the appliance may require additional ventilation. This can be achieved

by opening a window or by increasing the power of the mechanical exhausting system if installed.

Star Trivet: use star trivet whenever using a small pot.

Do not attempt to change the technical characteristics of the product because it can be dangerous.

- If you should not to use this appliance any more (or replace an old model), before disposing of it,

make it inoperative in conformity with current law on the protection of health and the prevention of

environmental pollution by making its dangerous parts harmless, especially for children who

might play on an abandoned appliance.

- Do not touch the appliance with wet or damp hands or feet.

- Do not use the appliance barefoot.

- The manufacturer will not be liable for any damage resulting from improper, incorrect or

unreasonable use.

- During, and immediately after operation, some parts of the cook top are very hot: avoid touching

them.

- After using the cook top, make sure that the knob is in the closed position and close the main tap

of the gas supply or gas cylinder.

-  If the gas taps are not operating correctly, call the Customer Care Department.

Abnormal Operation:

Any of the following are considered to be abnormal operation and may require servicing:

- Yellow tipping of the hob burner flame.

- Sooting up of cooking utensils.

- Burners not igniting properly.

- Burners failing to remain alight.

- Burners extinguished by cupboard doors.

- Gas valves which are difficult to turn.

In case the appliance fails to operate correctly, contact the authorised service provider in your area.

FIG. 3

FIG. 4

FIG. 5

(*) Air inlet – minimun section 100 cm

2

Warning: 

during operation the work surfaces of the

cooking area become very hot: keep children

away!

Summary of Contents for BGH60

Page 1: ...Instructions for the installation and advice for the maintenance MODEL BGH60 Instructions Manual MODEL BGH60 PLEASE READ THIS MANUAL BEFORE INSTALLING THE HOTPLATE COD 01099HS 31 07 2012...

Page 2: ...set and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and ca...

Page 3: ...trol knob left 15 Electric ignition button 16 Ultra rapid gas burner Wok 14 5 MJ 11 4 MJ 17 Trivet for ultra rapid burner 18 Burner 16 control knob Attention this appliance has been manufactured for d...

Page 4: ...n in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 MJ 22 24 Rapid 12 0 MJ 10 4 MJ 20 22 Semi rapid 7 1 MJ 6 2 MJ 16 18 Auxiliary 4 1 MJ 3 5 MJ 10 14 WARNINGS Burners with flame failure device may o...

Page 5: ...en who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage resulting fro...

Page 6: ...towards the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop C...

Page 7: ...nts given for the hole into which the appliance will be recessed see fig 8 Any adjoining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible material...

Page 8: ...s Natural Gas installations require the connection of a gas regulator at the appliance Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accorda...

Page 9: ...the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspond...

Page 10: ...appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all gas they are male conical type Re...

Page 11: ...the Only for use with U LPG label adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models BGH60 1...

Page 12: ...on on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or...

Page 13: ...p is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove the ta...

Page 14: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Page 15: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Page 16: ...16 0 1 2 3 4...

Reviews: