22
o
IMPORTANT: If you have any other cooking zone switched on,
this will not switch off at the end of the countdown time.
Electronic circuit’s temperature sensor
There is a temperature sensor situated inside of the hob top’s cooling
unit that constantly measures the temperature of the electronic circuits
that are contained in the hob.
o
In the event of the electronic circuits overheating, this will be
noted by the temperature sensor.
o
If the temperature sensor records a temperature that is above
80°C and the booster function is active, it will reduce the power
level from booster to level 9.
o
If the temperature sensor records a temperature that is above
89°C, the power level of the cooking zones will be reduced to
60% of the required level.
o
If the temperature sensor records a temperature that is above
94°C, the electronic circuit will shut down the appliance.
o
IMPORTANT: If the hob temperature sensor consistently
reduces the power of the cooking zones or shuts down the
appliance. This indicates that the hob has not been installed
properly or the opening for air ventilation is not large enough.
Steps should be taken to rectify this immediately.
Cooking zone temperature control
A temperature sensor is situated in the middle of each cooking zone
and is in contact with the glass.
o
In the event of a cooking zone overheating, this will be noted by
the temperature sensor.
o
If the temperature sensor records a temperature that is above
200°C and the booster function is active, it will reduce the power
level from booster to level 9.
o
If the temperature sensor records a temperature that is above
250°C, the power level of the cooking zone will be reduced to
60% of the required level.
o
If the temperature sensor records a temperature that is above
270°C, it will turn the zone off.