33
Butane
(G30)
30 65
127
-
Propane
(G31)
37 65
125
-
Natural
(G20)
20 115 -
286
Butane
(G30)
30 85
254
-
Rapid
Propane
(G31)
37 85
250
-
3.00 1.05
Natural
(G20)
20 135 -
286
Butane
(G30)
30 95
218
-
Wok
Propane
(G31)
37 95
214
-
3.50 1.80
o
Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section on the next page.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
o
Light the burner and set the
knob at the minimum
position.
o
Remove the knob from the
tap and place a small bladed
screwdriver in the centre of
the tap shaft.
o
Unscrew the adjusting screw, in order to increase the gas flow
or tighten the adjusting screw to decrease the gas flow.
o
The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
Summary of Contents for BC190.2TCSS
Page 1: ...1 KirThat BC190 2TCSS 90cm Single cavity gas range cooker with flame failure...
Page 43: ...43...
Page 44: ...44...