32
Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Remove the pan-stands,
burners and flame spreaders.
o
Unscrew the injector and replace it with the
stipulated injector for the new gas supply
(see table below).
Gas
consumption
Power
(kW)
Burner Types
of gas
Pressure
(mbar)
Injector
Marking
(1/100
mm)
g/h l/h
Max.
Min.
Natural
(G20)
20
72 -
95
Butane
(G30)
30 50
73
-
Auxiliary
Propane
(G31)
37 50
71
-
1.00 0.48
Semi-
rapid
Natural
(G20)
20 97 -
167
1.75
0.60