Baumatic BACG3034 Instruction Manual Download Page 16

AS/NZS 1869 (AGA Approved), 

10mm ID, class B or D, no more than 1.2m long and in accordance with 
AS5601. Ensure that the Hose does not come into contact with the hot 
surfaces of the hotplate, oven, dishwasher or other appliance that may be 
installed underneath or next to the hotplate. WARNING: Ensure that the 
hose assembly is restrained from accidental contact with the flue or flue 
outlet of an under bench oven. The hose should not be subjected to 
abrasion, kinking or permanent deformation and should be able to be 
inspected along its entire length. Unions compatible with the hose fittings 
must be used and connections tested for gas leaks. The supply connection 
point shall be accessible with the appliance installed. 

Before Leaving

 - 

Check all connections for gas leaks with soap and water. 

DO NOT 

use a naked flame for detecting leaks.  Ignite all burners 

individually and in combination, to ensure correct operation of gas valves, 
burners and ignition.  Turn gas taps to low flame position and observe 
stability of the flame.  When satisfied with the hotplate, please instruct the 
user on the correct method of operation.  In case the appliance fails to 
operate correctly after all checks have been carried out, refer to the 
authorised service provider in your area.  

GAS CONVERSION 

The appliance as supplied is for use with Natural Gas, if it is to be adapted 
for Universal LPG proceed as follows: 

• Isolate the appliance from the electricity and gas supplies.  

• If the appliance was previously installed for use with Natural Gas, remove 

the NG regulator and replace it with the Test Point Assembly.  A gas 
regulator suitable for a supply pressure of 2.75kPa should be part of the 
gas tank supply.  

• Remove the pan supports and burner assemblies.  

• Replace the injectors with the alternative type supplied Figure 3 below.  

• Use the appropriate thread sealant and check for gas soundness.  

• Replace the Natural Gas label with the Universal LPG label located next to 

15

Summary of Contents for BACG3034

Page 1: ...Instruction manual...

Page 2: ...GAS COOKTOPS...

Page 3: ...NTS Welcome to Think Letter page 3 General Information page 4 5 Warning and Safety Instructions page 5 6 Instructions for Use pages 7 10 Instructions for Installation pages 11 17 Technical Data page 2...

Page 4: ...et and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and car...

Page 5: ...ce finishes are particularly prone to heat damage or discolouration at temperatures lower than the above guidelines Contravention of the installation guidance given will be at the liability of the own...

Page 6: ...t is reserved to adjust and make any modifications deemed necessary without notification IMPORTANT NOTE WARNING and SAFETY INSTRUCTIONS This appliance complies with all current European safety legisla...

Page 7: ...INSTALLED IN A MARINE CRAFT OR IN CARAVANS IT SHALL NOT BE USED AS A SPACE HEATER Baumatic declines any responsibility for injury or damage to persons or property as a result of improper use or insta...

Page 8: ...he burners 1 Auto Ignition After pressing in and turning the appropriate knob anti clockwise to the large flame symbol the ignition spark will operate as long as the knob is pressed down When a flame...

Page 9: ...been established to enable the thermocouple to function The Safety Device is designed to stop the flow of gas to the burner head in the event of a flame out situation Abnormal Operation Any of the fo...

Page 10: ...slightly larger than the flame ring The flame should never exceed the diameter of the pan The bottom of the pan should be flat and wherever possible keep the lid on the pan when cooking For model BACG...

Page 11: ...t which can damage the appliance CLEANING THE APPLIANCE Always allow the appliance to cool down before cleaning to avoid a burn injury Do not use caustic or abrasive agents coarse wire wool or hard to...

Page 12: ...burner must be a suitable non combustible material for a height of 150mm for the entire length of the hob Any combustible construction above the hotplate must be at least 700mm above the top surface...

Page 13: ...inted on the packaging Invert the Hob and apply the sealing agent provided to match the outer perimeter edge If the sealing agent is a strip type the protective covering must be removed from both side...

Page 14: ...00 560 480 35 BACG7532 740 500 700 480 62 BACG9033 BACG9003 860 500 830 480 35 Figure 2 Attachment Screws 13 BACG6004 Location of Gas Connection 44mm from RH side 33mm from rear 43mm from LH side 34mm...

Page 15: ...of the appliance A duplicate label is supplied to adhere in an accessible area adjacent to the appliance This appliance is suitable for Natural Gas and Universal LPG you ensure that the available gas...

Page 16: ...in combination to ensure correct operation of gas valves burners and ignition Turn gas taps to low flame position and observe stability of the flame When satisfied with the hotplate please instruct th...

Page 17: ...he flow either clockwise to decrease or anti clockwise to increase the flame Use a screwdriver inserted down the gas tap rod or via the screw head adjacent to the rod for models fitted with a Flame Su...

Page 18: ...or the earth symbol or coloured green and yellow The wire coloured Blue must be connected to the terminal marked N or coloured blue or Black The wire coloured Brown must be connected to the terminal m...

Page 19: ...y supplies If a gas tap becomes stiff to operate proceed as follows Remove the control knobs pan supports burners and hob fixing screws clamps Remove the Hob from the worktop and remove any underside...

Page 20: ...onnect the appliance as described above Disconnect the gas pipe from the gas tap disassemble from the gas rail by removing the fixing screws When fitting a new tap ensure that a new gasket is used Re...

Page 21: ...IVERSAL LPG Model Large Medium Small Wok NG LPG NG LPG NG LPG NG LPG BACG3034 1 55 0 90 0 90 0 53 BACG3035 1 15 0 70 0 65 0 45 BACG6004 1 18 0 69 0 9 0 53 1 60 0 97 BACG7531 1 55 0 90 1 18 0 69 0 9 0...

Page 22: ...el Large Medium Small Wok Total Max Max Max Max MJ h BACG3034 10 8 3 7 14 5 BACG3035 14 0 14 0 BACG6004 6 3 3 7 12 5 28 8 BACG7002 10 8 6 3 3 7 14 6 41 7 BACG7532 6 3 3 7 14 0 34 0 BACG9033 10 8 6 3 3...

Page 23: ...Baumatic www baumatic com...

Reviews: