TECHNICAL DATA
ELECTRICAL DETAILS
Rated Voltage:
230V ac 50Hz
Supply Connection:
Switched Double-pole Isolator with 3mm contact separation
POWER INPUTS AND PROTECTION RATING
Model
Max
Total
Min Fuse
kW
Amps
Protection Rating
B65
6.0
26.1
30A
BE2SS
3.5
15.2
16A
BVC2SS
2.9
12.6
16A
Mains Supply Connection Cable:
3 x 2.5mm2 Type H05 RR-F
<
HAR
>
marked
NOTE:
For cable connection details, see diagram on appliance base plate.