Electrical Connection
This appliance must be installed by a competent person, such as one holding NICEIC Registration and
in accordance with the latest edition of the IEE WIRING Regulations.
Before connecting the appliance, make sure that the supply voltage marked on the rating Plate
corresponds with the mains supply voltage.
WARNING – THIS APPLIANCE MUST BE EARTHED
Depending on the power input of the model to be installed, connection will require a 30 Amp protected
supply using a switched double pole isolating unit having a minimum 3mm contact separation and a
BS6007 3 core cable.
Care must be taken to avoid the cable being in contact with hot parts of the appliance. The isolating
unit should be placed in an easily accessible position adjacent to the appliance.
The mains terminal block is located on the underside of the hob and the terminals are accessible by
removing the terminal block cover by removing the cover screw. The mains supply connection cable
type should be H05 RR-F <HR> marked or above.
Before connecting the appliance to the mains supply the installer must check that the voltage stated on
the appliance rating plate (located on the underside of the hob) is exactly the same as the mains voltage
supply.
L1
L2
L3
N
N
Earth
Mains cable entry point