Installation instruction
Installation diagram
Distance from wall
should be over 50mm
Distance from ceiling
should be over 200mm
Distance from the wall
should be over 50mm
To get detail installation information,
please go to: docs.bauknecht.eu
NOTE:
The figure is only a simple
presentation of the unit, it may not mutch
the external appearance of the product you
purchased. Installation must be performed in
accordance with th national wiring standard
by authurized service people only.
Distance from floor
should be over 2500mm
Indoor unit
Outdoor unit
Air intake distance from the
wall should be over 250mm
Air intake distance from the
wall should be over 250mm
Air outlet distanc
e fr
om the w
all
should be o
ver 500mm
Over
250mm
When install interconnection cord , make sure that the color of wires and the terminal No. of outdoor unit shall be
same as those in indoor unit.
Cable Specifications
Capacity (Btu/h)
Power cord
Power connecting cord
Type
Normal cross -
sectional area
Type
Normal cross -
sectional area
7K, 9K, 12K
H07RN-F
1.0mm
2
X3
H07RN-F
1.0mm
2
X5
18K
H07RN-F
1.5mm
2
X3
H07RN-F
1.5mm
2
X5
24 K
H07RN-F
2.5mm
2
X3
H07RN-F
2.5mm
2
X5