![BAUKER DG5500E Instruction Manual Download Page 36](http://html1.mh-extra.com/html/bauker/dg5500e/dg5500e_instruction-manual_2709219036.webp)
Preliminary Review
70
69
Oil level
Check the oil level before operating the generator at all times.
1- Unscrew the filter cap and clean the oil dipstick using a cloth.
2- Reinsert the dipstick in the filter.
3- If the oil level is below the mark on the dipstick, refill
with oil up to the maximum level on the dipstick.
4- Reinsert the filter cap.
Oil level
Check the oil level before operating the generator at all times.
1- Unscrew the filter cap and clean the oil dipstick using a cloth.
2- Reinsert the dipstick in the filter.
3- If the oil level is below the mark on the dipstick, refill
with oil up to the maximum level on the dipstick.
4- Reinsert the filter cap.
Fuel level
1- Check the fuel level on the indicator located above
the fuel tank. "E" means it is Empty and "F" indicates
it is Full.
2- If you need to refill with fuel, turn the cap in an
anticlockwise direction.
3- Check the filter for dirt or abnormalities. Clean the filter
if necessary.
4- Refill up to the indicator located inside the filter.
Use unleaded 93 octane gasoline. Use funnels or
cans with spouts to avoid spilling fuel. After refilling,
clean with a dry cloth any fuel residues from
the generator surface.
5- Reinstall the fuel tank cap.
Operation Instructions
diesel generator