Operating Manual for
BAUER ECOSTAR 6000
15
Pressure mode:
Select whether the pressure switch/sensor is needed for starting or
monitoring. With monitoring, the start function is also activated. During
measuring (only possible with pressure sensor), only the value in the Info
menu is displayed.
Monit. time (pressure) [min]:
Time after which the ECOSTAR responds to the pressure switch/sensor
(pressure fluctuations)
Min. pressure [bar]:
If the connection pressure falls below this value, the irrigation is stopped
(pressure sensor)
Unit [mm-m/h]:
Select whether the retraction speed is entered as an irrigation amount
(mm) or a speed (m/h).
To use this function, the nozzle values must be set on page 4 as well as the strip width on
page 3!!!
Low-pressure start:
With the setting “Open valve”, the valve opens upon pressing of the start
button or if pressure is low or entirely absent.
Flow impulse [lit/imp]:
This setting is used by the water consumption meter. The value to be
entered here is shown on the water meter, if present.
Flow:
If the flow is known, it is entered here.
However, if the flow is not precisely known, enter 0 here. Otherwise the
speed is calculated based on the flow.
In this case, the following parameters must be entered:
Nozzle diameter,
nozzle pressure, nozzle characteristics alpha and strip width.
Strip width:
The strip width can be found in the conversion table on the RAINSTAR