3
01/201
1
Operation
The B-Timer is activated when starting the
compressor. Compressor operation is indi
cated by the flashing “h” symbol.
To switch on the B-Timer press one of the keys on the display.
Main menue will be displayed (Fig. 5).
If no key is pressed within 1 minute, the in
dication will return to the main menue. After
2 minutes the B-Timer is switched off, if no
compressor operation is detected.
Function Display
To
display
the desired function, press the se
lect key (
).
Press
key. Remaining filter capacity is shown, Fig. 6)
Press
key again. Remaining operating hours to service interval
A (500 hours or annually) are shown (Fig. 7).
Press
key again. Remaining operating hours to service interval
B (1000 hours or annually) are shown (Fig. 8).
Press
key again. Remaining operating hours to service interval
C (2000 hours or biennially) are shown (Fig. 9).
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9