MNL-0391
April 26, 2007
Page 5
BAUER
COMPRESSORS
1.5
Air Flow Diagram
See Figure 1-4.
The air is drawn in through the Telescopic Tube (1) through the Intake Filter (2) and is compressed to
final pressure in the Cylinders (3, 4 and 5). It is recooled by the Intercoolers (6 and 7) and the After-
cooler (9). The pressure of the individual stages is controlled by Safety Valves (10 and 11). The com-
pressed air is cleaned in the Intermediate Separator (8) and purified in the P0 Filter System (13). The
Intermediate Separator and P0 Filter System are drained by the Condensate Drain Valves (15). The
Pressure Maintaining Valve (16) provides a constant pressure within the P0 Filter System. The purified
compressed air then passes through the Fill Hose (17) and Fill Valve (18) to the bottles to be filled. Fill
pressure is indicated by the Final Pressure Gauge (19).The Final Safety Valve (12) is adjusted to blow
off at the pressure selected.
Figure 1-2
Internal Air Flow Diagram
1. Compressor Air Intake Extensions
2. Intake Filter
3. 1st Stage Cylinder
4. 2nd Stage Cylinder
5. 3rd Stage Cylinder
6. 1st/2nd Stage Intercooler
7. 2nd/3rd Stage Intercooler
8. Intermediate Separator
9. After Cooler
10. 1st Stage Safety Valve
11. 2nd Stage Safety Valve
12. Final Pressure Safety Valve
13. P0 Filter System
14. Triplex
®
Longlife Cartridge
15. Condensate Drain Valve
16. Pressure Maintaining Valve
17. Fill Hose
17
13
14
15
12
11
8
15
9
5
2
3
4
6
10
7
1
16