background image

Gea V.06 

12 

2018 

PROBLEM 

CAUSE 

SOLUTION 

The  items  inserted 

in  the  cabinet  are 

not  sanitized  and 
cleaned  (they  still 

have a bad smell) 

 

An  excessive  number  of 
items  to  be  sanitized  and 

cleaned has been inserted 

The  items  inserted  into  the 
machine  must  be  as  far  apart  as 

possible,  so  that  their  whole 

surface is exposed to the hygienic 
action of the ozone 

The  inserted  load  has  an 
excessive  bacterial  load 

(e.g. 

particularly 

malodorous 

...) 

that 

requires  a  particularly 

prolonged 

ozone 

exposure 

Perform  an  additional  sanitizing 
program.  

The  effectiveness  of  the  sanitizing 
and  cleaning  treatment  depends 

on  the  type  of  garments  and  the 

bacterial load present 

 

There  is  an  accumulation 
of  dust  on  lamps  and/or 

the vacuum grille.  

The 

accumulating 

dust 

progressively 

reduces 

the 

performance  of  the  machine. 
Remove  the  dust  from  the  lamps 

and  the  grille  using  a  vacuum 

cleaner.  Pay  particular  attention 
when  cleaning  the  lamps  as  they 

are  very  fragile.  Do  not  touch  the 
glass  of  the  lamps  with  your 

fingers  so  as  not  to  leave 
fingerprints  and/or  fat  residues 

which  could  compromise  their 

durability (fig. 2) 

When  you  open  the 
door,  at  the  end  of 

the  program,  you 
will  detect  a  very 

intense  and  pungent 

odor of garlic 

The  ozone  blaster  does 
not function properly 

Have 

the 

correct 

operation 

checked 

The  door  is  not 

locked  during  the 
execution 

of 

program 

The  door  has  not  been 

properly closed 

Make  sure  the  door  is  properly 

closed before starting the program 

The  safety  locking  of  the 

door is faulty 

Disconnect  the  machine  and  have 

it checked by a technician 

Programs  do  not 
start and the display 

shows  the  message 

CLOSE THE DOOR

 

The  door  has  not  been 
properly closed 

Make  sure  that  the  door  closes 
properly  and  that  the  safety 

device,  located  near  the  door,  is 

well positioned and secured. If the 
message 

CLOSE  THE  DOOR

  is 

still  displayed  then  the  device  is 
faulty and must be replaced 

The  machine  does 

not start or does not 
work 

The fuses are damaged 

Check the fuses located inside the 

machine  (fig.  3).  To  access  the 
fuse compartment, remove the top 

cover of the machine. 

F1= 5x20 - 250V  - F 1,25 A 
F2= 5x20 - 250V  - F 4 A  

 
 

 
 

Summary of Contents for GEA

Page 1: ...36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is the property of BATTISTELLA B G S r l Any reproduction is prohibited The Company res...

Page 2: ...TOP AND DOOR OPENING 8 11 DOOR OPENING CLOSING 8 12 ADJUSTABLE SHELF 9 13 OZONE BLASTER FAULT 9 14 ABNORMAL SHUTDOWN OF THE PROGRAM NO ELECTRICITY 9 15 CHANGE LANGUAGE 10 16 PLUG CONNECTION ONLY THE M...

Page 3: ...e the product in a manner different than the one specified in this manual 1 MACHINE FEATURES MODEL GEA ELECTRICAL POWER 230 V 50 60 Hz TOTAL INSTALLED POWER 143 W BLOWING MOTOR POWER 73 W OZONE LAMP P...

Page 4: ...not play with the device To make the hazards more obvious adhesive symbols whose meaning is explained below are placed on the critical points of the machine 3 PACKAGING OPENING 1 When receiving the m...

Page 5: ...operation 8 Keep the power supply cord away from hot surfaces and make sure it is not crushed by doors or trampled 9 The machine must be positioned so that there is a distance of no less than 50 cm be...

Page 6: ...shed credit N B both in the self with centralized coin mechanism operation and in the built in coin mechanism mode at the end of the cycle all additional residual credits are reset It is therefore rec...

Page 7: ...here are many particularly malodorous garments or items in the cabinet 6 Once the program has been selected the green light turns off and indicates that the cabinet is busy and is running the sanitizi...

Page 8: ...there are few items inside the cabinet or items that are not particularly malodorous Program 2 MEDIUM 35 minutes suitable for a medium load of clothes inside the cabinet Program 3 LONG 40 minutes suit...

Page 9: ...he seat 2 Pull the lever towards you to open Do not force the opening of the machine door during the execution of a sanitizing program always wait for the end of the running program Only when the mess...

Page 10: ...ork properly Check and replace the parts if necessary To reset the machine it is necessary to switch it off and on again using the master switch only after having eliminated the cause of the warning 1...

Page 11: ...programs It is recommended to use a centralized external coin mechanism able to manage 2 bonuses The operation will be as follows 1 You set a basic price in the centralized coin mechanism for example...

Page 12: ...lacing lamps and or ballasts or any material with non genuine parts 18 MECHANICAL RISKS The operator must pay attention to the following situations defined as hazardous from the mechanical point of vi...

Page 13: ...ouch the glass of the lamps with your fingers so as not to leave fingerprints and or fat residues which could compromise their durability fig 2 When you open the door at the end of the program you wil...

Page 14: ...by means of a support Not being a rigid package it is not very resistant to shocks fragile material therefore pay the utmost attention when handling the packaged device do not use it as a stool or as...

Page 15: ...re are damages deriving from a fortuitous event fire short circuit or due to third parties tampering when using the machine for a purpose different than the one specified in this manual when using non...

Page 16: ...ase Exclusion of liability for indirect damage In no case Battistella B G S r l will be held liable for damages including without limitation indirect damage due to loss or loss of earnings business in...

Page 17: ...Gea V 06 16 2018 26 ELECTRICAL DIAGRAM...

Page 18: ...Gea V 06 17 2018...

Reviews: