Rev. H-070708
P/N VDC24041-MNL
BatteryMINDer
®
Model 24041
Page 12
1
10
9
8
7
6
4
5
3
2
11
12
1) Battery clip cordset w/ qwik connect plug (pgs.13, 16)
2) Ring terminal cordset w/ qwik connect plug (pgs. 13, 16)
3) Mounting tabs
4) Input power cordset (pg. 13, 18)
5) Output cord w/ qwik connect plug (pg. 13, 16)
6) Temperature sensor input connector (pg. 13, 17, 21)
7) Charge rate selection button (pg. 13, 17, 18)
8) Battery type selection button (pgs. 13, 17, 18)
9) Stop/Restart selection button (pgs. 13, 17, 18)
10) LED indicators for power, connection, fault, battery
condition, charge status (pgs.13-15, 18–20, 24)
11) 12 Volt Power cordset (Optional)
12) Temperature sensor with cord and ring terminal (pgs. 17,
21 - 24) (Optional)
2 A
9LL=JQ'#(=J
¸
Charger / Maintainer /
Full Time De-Sulfator-Conditioner
24-Volt @ 1/2/4 Amp
Model 24041
4 A
1 A
Select
Charge Rate
Select
Battery Type
Green = Power ON
ERROR:
Red = Polarity Reversed
/ Battery = less than 6-Volts
*
Red (Blinking) = Battery not fully charged -
charger in float-maintenance mode
*
Charge - Float
Green (solid) = Charging
Green (blinking) = Float (maintenance)
*
See Instruction Manual
PRESS
PRESS
PRESS
Battery Condition Indication
Power On & Battery Connected
Before Start Charge:
Green = OK - Accepted
Yellow = Weak / Sulfated / Deep Discharge
*
After Charge:
Green = Good
Yellow = Sulfated / Weak
*
MAINTENANCE
(FLOAT)
AGM
GEL
FLOODED
VDC Electronics, Inc.
800-379-5579 (ET)
www.batteryminders.com
U.S. Patented & Patent Pending
Stop
Restart
Hold for 5 sec. for full reset
For Lead-Acid
Batteries ONLY