5-
To activate this refresh feature, simply press and hold the ‘Refresh’ Button for 3 Seconds until the Refresh LED
begins flashing (BLUE).
Once the charger has entered the refresh charging stage, the process will automatically time out after 24 hours
or you can manually stop this process at any time by pressing and holding down the ‘Refresh’ Button for 3
seconds.
Equalisation Process (For Calcium Batteries Only)
This Battery Charger also provides a battery equalisation function.
What does this feature do?? –
Equalisation helps to maintain and balance your battery cells by reversing the
high concentration of electrolytes from the bottom of your battery.
This allows all the cells to charge evenly and makes you get the most out of your battery.
You can you this feature weekly to ensure your battery is always well maintained.
Note:
If you select the Calcium battery type, the charger will automatically run the equalisation stage during
the charging cycle.
The Equalisation process will not work for AGM&WET/GEL Batteries.
Depending on the charge rate selected, this process will time out after 1 to 3 hours.
Equalising voltage is set to 16.2V for Calcium batteries.
4. Disconnecting the Battery charger from Battery.
(a) If the Battery is out of the vehicle.
1. Switch OFF and Remove the AC Power Socket from the outlet.
2. Remove the Black lead and then the Red lead.
3. Check electrolyte levels if possible. (As they may need topping up with distilled water after charging)
(b) If the Battery is in the vehicle.
1. Switch OFF and Remove the AC Power Socket from the outlet.
2. Remove the lead from the vehicle chassis.
3. Remove the lead from the battery.
4. Check electrolyte levels if possible. (As they may need topping up with distilled water after charging)
CHARGING STAGES