background image

1)  Fit the wall fixing brackets to bath timber frames to 

  allow the bath to be secured to walls that abut the 

 bath.

2)  Drill and affix Taps.

3)  Fit wastes, overflow and waste traps supplied.

4)  Place bath into position & adjust to minimum 

  height. The bath is adjusted at its lowest height to 

  ensure door 'step in' threshold is kept at a 

 minimum.

  Note: It is advisable to fix batten runs on to the 

  floor under the bath feet to avoid extending the 

  legs to far & to ensure feet sit squarely and flat. On 

  a wooden floor batten runs 

  (minimum 3” x 2”) should be positioned squarely 

  across the floor boards to spread & support the 

 load.

5)  Level bath in all planes and lock the feet. 

6)  Mark wall fixings and plumbing runs.

7)  Remove bath, drill wall fixings and run plumbing 

  into position.

8)  Re-position bath and affix to wall and to floor. 

  Ensure the 2  bath feet under the doorway is 

  cranked up to support the foot well as well as the 

  doorway integrity.

9)  Connect plumbing. The wastes may be run 

  independently or joined by use of a tee, inserted 

  after the in line traps.  Refer to fitting guides for the 

  Thermostatic valve and Pump if supplied.

10)   Test plumbing for leaks and pump operation.

11)   Fill bath to maximum and leave for about 30 

    minutes to test the door seal.

12)  Whilst bath seal is tested position and trim to size 

    front and side panels if required (front panel lips 

    into top rim and is pre-cut to bath height). 

13)  End panel will require batten support along floor 

    and on the vertical corner sides. Mark bottom of 

    panels onto floor base and on the vertical and fit 

   accordingly.

14)  Refit front and side panels. Drill through bottom 

  into batten. Affix panels using screws and caps. Do 

  not use Silicone sealant as this prevents service 

 access.

15)  Finally drain bath and Leave the Door Open to 

    prevent over compression and wearing of the seal.

16)  Instruct customer on the use of the bath.

2

STANDARD FITTING GUIDE

REFER TO 'OPERATING/CARE AND MAINTENANCE INSTRUCTIONS' AND LEAVE COPY WITH CUSTOMER. 

DO NOT LEAVE DOOR IN LOCKED POSITION ON COMPLETION.  ADVISE CUSTOMER THAT THE DOOR 

SHOULD BE LEFT UNLOCKED WHEN NOT IN USE IN ORDER TO PRESERVE THE SEAL.

April 2014

Made in UK