Multiplier Settings
Sections S7-1 and S7-2 configure the multiplier used with the Time Delay Selector Switches.
For a times one (X1) multiplier, S7-1 and S7-2 are placed in the down position.
For a times 10 (X10) multiplier, S7-1 is placed in the up position and S7-2 is placed in the down position.
A times 10 multiplier is also obtained when S7-1 is placed in the down position and S7-2 is placed in the
up position.
For a times 100 (X100) multiplier, S7-1 and S7-2 are placed in the up position.
Cycles/Seconds Settings
S7-3 either selects cycles or seconds as the unit of measure for the definite time delay. S7-3 is placed in
the up position to select cycles. The down position of S7-3 selects seconds.