Physical Interface
Basler ace USB 3.0
57
5.7
Opto-isolated Input (Pin 2/Line 1)
The camera is equipped with one dedicated opto-isolated input line designated as Line 1. The input
line is accessed via the 6-pin connector on the back of the camera (pin 2, see
Figure 34
).
In addition, the camera has two direct-coupled GPIO lines, Line 3 and Line 4, that can both be used
as input lines. They are described in Section 5.9 on
page 63
.
5.7.1
Electrical Characteristics
The opto-isolated input line has the advantage of being distinctly more robust
against EMI than a GPIO line used as an input. However, when using the opto-
isolated input line, the delays involved are longer than for a GPIO line.
DANGER
Electric Shock Hazard
Risk of Burn or Death.
The power supply used must meet the Safety Extra Low Voltage (SELV) and
Limited Power Source (LPS) requirements.
A suitable power supply is available from Basler. Contact your Basler sales
representative to order a power supply.
WARNING
Fire Hazard
Risk of Burn
The power supply used must meet the Limited Power Source (LPS) requirements.
A suitable power supply is available from Basler. Contact your Basler sales
representative to order a power supply.