BASI BTC284U Operation Manual Download Page 4

 
 

Error Messaging 

12 

 

 

Message Parameters Error 

type 

FAiL 

all 

Incorrect 
memory  

br" 

Service 
required! 

ER01 GrAd 

Out of range 

ER02 \t 

Out of range 

ER03 \b 

Out of range 

ER04 %[L 

Out of range 

ER05 %[H 

Out of range 

ER06 

%[L

,

 

%[H %[L

%[H

 

ER11

ER21 ym1

,

 

ym2 

Out of range 

ER12

ER22 y\1

,

 

y\2 

Out of range 

ER13

ER23 HLe1

,

 

HLe2 

Out of range 

ER14

ER24 [e1

,

 

[e2 

Out of range 

ER15

ER25 me1

,

 

me2 

Out of range 

ER16

ER26 %[1

,

 

%[2 

Out of range 
(

%[L

 

%[H

)

 

ER17

ER27 %[

x

 

-

 

me

 x

 

Lower than 
Input 
Low Range 
Limit 

ER18

ER28 %[

 x 

+

 

[e

 x

 

Exceeds  
Input 
High Range  
Limit 

ER29 Addr 

Out of range 

 

 

In some cases, 
BTC284U finds 
non-conformities 
in parameter values 
that must be corrected 
before operating 
at Basic level. 

 

The device indicates 
such kind of problems  
by displaying 
error messages 
as given on the left.

 

 

If 

FAiL

 appears 

on the display, 
try debugging 
by turning  
the power off/on.  

 

If the problem persists, 
press and hold 

 or 

send command 

error

 

via the communication 
interface to restore 
the default (factory) 
settings. 

  

 

 

 

 

 

 

 
 

Parameter Programming 

 Some parameters  

are accessible only 
when the respective  
functionality is installed. 
(see 

'

Specifications

'

).

 

 
 
 

 
 

 

 

-  Changing  

Point Position 

value

 

reflects the real value 
of all parameters 
with ISU. 

E.g.: changing  

Point Position 

value 

from (0) to (0.0) 
would change 
a set-point value 
of 100 to 10.0. 

 

Controller parameters 

 

BTC284U is a programmable device whose  
service behavior is determined by a set  
of parameters. All the parameters, along  
with their names, symbols, and value ranges,
are given in Table 1.

 

Setting numerical parameter value 

 

Enter parameter value adjustment mode 
(see '

Program Levels

').

 

 

The whole part of the value together with 
the left zeroes appears on the display,  
and the rightmost digit blinks.

 

 

To select another digit, press 

 

.

 

 

The 3 rightmost digits can accept values 
from 

0

 to

 

9

, and the leftmost digit 

can also accept the values 

-

 and

 

`

.

 

 

To increase or decrease the blinking digit 
value, use respectively 

 or 

 

.

 

 

Confirm the adjusted value by pressing 
simultaneously

 

 + 

 

or 

 + 

.

 

 

If the new value has not been confirmed  
and no key has been pressed for a certain 
period of time, value adjustment 
automatically ceases, and the parameter 
retains its initial value.

 

Setting symbolic parameter value 

 

Enter parameter value adjustment mode 
(see '

Program Levels

').

 

 

Read the blinking parameter value. 

 

To change the value, use 

 or 

,  

and to confirm, press 

 + 

  

or 

 + 

.

 

 

If the new value has not been confirmed  
and no key has been pressed for a certain 
period of time, value adjustment  
automatically ceases, and the parameter 
retains its initial value.

 

 

 
 

Program Levels 

 

 

 
 
 
 
 

 

Basic level 

At Basic level, BTC284U indicates 
the measured input value (PV) 
with a resolution, according to 
the 

Point Position

 parameter. 

 

If the whole part of PV cannot be 
entirely displayed, the unit 
generates blinking 'overflow' 
message (

oL

 or 

-oL

,  

depending on PV sign). 

 

If PV is out of its operating range 
(the input range according  
to Table 1, extended by 5%  
on both sides), the device displays 
blinking symbolic message:  

<__>

 (under-range) or 

 

{++}

 (over-range).  

When PV is out of physical range, 
the unit displays 

----

 

Upon entering Basic level,  
BTC284U may display  
the 

init

 message, 

indicating that some time  
is necessary for filter initialization. 

 

The 

noiS

 message may appear 

as a result of the peak filter 
operation (see '

Input filtration

'). 

 

To enter parameter value 
adjustment mode for 

Set Point 1

press and hold

 

 until 

%[1

 

appears on the display.  
To view the Set-point value,  
release the key. 

 

To enter parameter value 
adjustment mode for 

Set Point 2

,

 

follow the same procedure, 
but start with the 

 key. 

 
 

 

 

 
 

Program Levels 

 

 

 

 

 

 

Parametric level 

This level contains the control  
algorithm parameters. If no relay output 
is installed, this level does not show up. 

 

Enter from Basic level by pressing 
and holding 

 until 

PAr

 appears 

on the display. Release the key. 
If the key is not released on time,  
BTC284U enters Configuration level. 

 

Choose a parameter  
using 

 and 

 

 

To enter parameter value  
adjustment mode, press 

 

 

If no key has been pressed  
for a while, the device automatically 
returns to Basic level, storing all 
confirmed changes. 

 

For quick exiting and saving, 
use key combination 

 

+

 

 

Configuration level 

This level contains the configuration 
parameters of the device. 

 

Enter from Basic level by pressing 
and holding 

 until 

conF

 

appears on the display.  

 

To access and adjust 
the configuration parameters,  
follow the algorithm described  
in 'Parametric level'. 

 

 

 

 

 

Reviews: