17
E
E
D
D
6
Force the pole rope loop tight
against the connector body. It
may take a few light taps of a
hammer to properly seat the
line. [D]
7
Place the heat-shrink cap on
the end of the line, and secure
using a blow dryer. Do not
overheat the rope. Excess heat
could damage the line.
8
Position one half of the rope
clamp between the marks. It
must be configured to meet
the other half and allowing the
alignment of the screw holes.
While avoiding damage to the
clamp, push or squeeze the
rope into the clamp. This may
be done with a pair of pump
pliers. [E]
9
Repeat the procedure with the
other half of the clamp.