Components

Advance Termite Bait Station (TBS) is pre-assembled and 
consists of:

1) Advance Quik-Lock

®

 Cap with bar code

2) Advance Termite Monitoring Base (TMB)
3) Advance Termite Inspection Cartridge (TIC)
4) Advance Termite Bait Station (TBS)

The top of the Advance TBS is technician friendly for easy 
access to the interior compartment of the station. The 
station cap is opened with a special device called The 
Spider

®

. Inside the in-ground station is a combination of 

a highly preferred wood monitor and a Termite Inspection 
Cartridge (TIC) that contains Puri-Cell

®

 monitoring tablets, 

the pre-bait. Termites will initially feed and aggregate in the 
lower Termite Monitoring Base (TMB), then readily forage 
upward and feed on the Puri-Cell tablets. This combina-
tion enables the technician to inspect and detect termite 
activity in the station with minimal disturbance to termites 
in the station.

Placement

Place the Advance TBS in the soil around the perime-

ter foundation of a structure. The operator should identify 
critical areas where stations should be installed including, 
but not limited to, termite active tubes and infested wood. 
Other critical areas may include infested materials and ar-
eas conducive to termite activity including wood-to-soil 
contact, moist soil around downspouts, air conditioner 
drain lines, sprinkler heads and mulch beds.
The recommended spacing between stations is 10 feet 
with the maximum spacing between stations not to ex-
ceed 20 feet if access to soil is unrestricted.

Installation

Tools required: 2-3/4 inch 
hand auger or an electric or 
gaspowered auger bit meas-
uring 2-1/2 inches in diam-
eter. 
When using a 2-1/2 inch au-
ger in heavy soil such as clay 
or clay loam, the hole may 
need to be slightly enlarged. 
Also, in heavy soil, it is recommended that the depth of 
the hole extend below the bottom of the station for ex-
cess water drainage. In areas with heavy thatch or dense 
grass (i.e. St. Augustine, Bermuda) a sod cup cutter can 
be used so the station does not extend above the soil 
causing a tripping or mowing hazard.
Once the soil is removed from the hole, insert the Ad-
vance TBS in the hole and press down. The top of the sta-
tion should rest on the soil without extending significantly 
above the ground.

 

2  

4

 Hand 

Power

Quick Installation/Service Guide

BASF Corporation

26 Davis Drive

Research Triangle Park, NC 27709

81041164  NVA 2015-05-506-0626