10.8 Programming User Code to “OUTPUT 2” (F)
To carry out this programming step the code lock should now be in programming
mode (see Chapter “10.1 Entering Programming Mode”).
Note that the user numbers for “OUTPUT 1” (E) must be 4 digits long and those
for “OUTPUT 2” (F) must be 3 digits. The user code can be 4-8 digit long.
User numbers cannot be assigned twice.
To programme a user code to the relay output 2 “OUTPUT 2” (F) enter the following key
combination:
51 3 digit user number
4-8 digit user code
# #
Example:
51 113
9877
# #
10.9 Deleting User Code for “OUTPUT 2” (F)
a) Deleting all User Codes for “OUTPUT 2” (F)
To delete all user codes programmed to the relay output “OUTPUT 2” (F) enter the following
key combination:
5
0000
#
b) Deleting Individual User Codes for “OUTPUT 2” (F)
To delete individual user codes programmed to the relay output “OUTPUT 2” (F) enter the
following key combination:
Example delete user code:
52 Enter the user code of “OUTPUT 2” (F) to be deleted
#
Example delete user code:
52 5648
#
c) Deleting User Codes using the User Number
To delete user codes from “OUTPUT 2” (F) using the corresponding user number, enter the
following key combination:
53 Enter the user number of the user code to be deleted
#