 Operating instructions

Basetech Cost Control 

Item no. 125417 

(CH)

Item-No. 125416 

(FR/CZ)

Item-No. 125414 

(UK)

Intended use

The energy cost measuring device is intended for measuring and analysing  consumption details of electrical 

devices. The measuring device is connected easily between the mains socket and the electric device and 

requires no additional installation. It is only to be used with standard domestic mains sockets with a nominal 

voltage of 240 V/AC. The max. nominal  performance must not exceed 3120 watts.
To calculate the costs, the current valid electricity rate can be entered. Further, the device provides a cost 

forecast per day/month/year. 
The consumption details can be displayed and adjusted on the device even when it is unplugged from a 

power socket. To do this, the device contains two button cell batteries. The device is only to be used with 

the specified batteries.
The measuring device is not officially calibrated and therefore must not be used for billing purposes.
The measuring instrument must not be used when it is open, i.e. with an open battery compartment or when 

the battery compartment cover is missing. Do not make measurements in damp rooms or under unfavour-

able ambient conditions.
Unfavourable ambient conditions are:
-  Wet conditions or high air humidity,
-  Dust and flammable gases, vapours or solvent,
-  Thunderstorms or similar conditions such as strong electrostatic fields etc.
Any use, other than the one described above, may damage the product. Moreover, this involves hazards 

such as e.g. short circuit, fire, electric shock, etc. It is not allowed to modify or rebuild any part of the product! 
Read the operating instructions carefully and keep them for later reference.
The safety instructions are to be observed without fail!

Package contents

•  Energy cost measuring device
•  2 button cell batteries (type LR 44 or identical in design)

Up-to-date operating instructions           

Download the latest operating instructions via the link www.conrad.com/downloads or scan the QR code. 

Follow the instructions on the websit 

Explanation of symbols 

   An exclamation mark indicates important instructions in this operating manual which must be 

observed without fail.

  This product has been CE tested and complies with the required European guidelines.

  Only to be used in dry indoor areas.

CAT II 

 The device corresponds to the excess-voltage category II for implementation in devices that are 

directly connected to the public grid via a mains plug.

Safety Instructions

Please read all the instructions before using this device, they include important informa-

tion on its correct operation.
The warranty will be void in the event of damage caused by failure to observe these safety 

instructions! We do not assume any liability for any consequential damage!
We do not assume any liability for material and personal damage caused by improper use 

or non-compliance with the safety instructions! The warranty will be void in such cases. 
•  This device left the manufacture’s factory in a safe and perfect condition. 
•  The unauthorized conversion and/or modification of the product is inadmissible for reasons 

of safety and approval.

•  If you have doubts about how the equipment should be operated or how to connect it safely, 

consult a trained technician.

•  Observe the safety and operating instructions of any devices you connect to the device, as 

well as those you find in the individual chapters of these operating instructions.

•  Never touch the device with wet or moist hands. There is danger of a life-threatening electric 

shock.

•  Keep the unit out of the reach of children. It is not a toy.
•  On industrial sites, the accident prevention regulations of the association of the industrial 

workers’ society for electrical equipment and utilities must be followed.

•  Since the device generates heat when in use, ensure there is sufficient ventilation provided; 

do not cover the housing!!If you have a reason to believe that the device can no longer be 

operated safely, disconnect it immediately and secure it against being operated unintention-

ally. It can be assumed that safe operation is no longer possible if:

 - the device is visibly damaged,
 - the device no longer works and
 - the unit was stored under unfavourable conditions for a long period of time or
 - it has been subjected to considerable stress in transit.

•  You should also heed the additional safety instructions in each chapter of the operating inst-

ructions for the connected devices.

•  Never switch the device on immediately after taking it from the cold into a warm environment. 

Condensation that forms might destroy your device. Allow the device to reach room tempera-

ture before  switching it on.

Description of the Parts 

230 3680

6.20

V

W

W

T O TA L

k W h

1

2

3

4

5

6

7

8

9

SET

1  Protective-earth contact socket with child protection 
2  Control and setting key „

F

“ (downwards)

3  Control and setting key „

S

“ (upwards)

4  Display: Display area „bottom“
5  Display: Display area „Left“
6  Display: Display area „Right“
7  Rear battery compartment
8  „SET“ key for parameter setting
9  Control and setting key „

J

“ (Confirmation)

Display indications and Symbols

S

 

Up symbol

F

 

Down symbol

J

 

Confirmation symbol

SET Adjustment
MAX 

Maximum value display

POWER FACTOR  Display of the power factor CosPhi
TOTAL 

Total value

COST 

Cost display

TIME 

The actual operating time for the electric consumer load, e. g. for  fridges.

FORECAST 

Calculated cost forecast

DAY 

Cost forecast per day

MONTH 

Cost forecast per month

YEAR 

Cost forecast per year

Volt (unit for electric tension)

Ampere (unit for electric current)

Hz 

Hertz (unit for frequency)

Watt (unit for effective power)

COS 

Power factor (factor for the phase displacement of V and A)

kWh 

Kilowatt hour (Unit for energy usage)

Start-up

Inserting/Replacing the Batteries

Before using for the first time or when the display does not show any values after pressing the button, the 

coin cell batteries must be inserted or replaced. 
The batteries are used to ensure that the set parameters and measured values are saved in the device even 

when it is unplugged.  

  The battery compartment (7) must only be opened if the device is unplugged  .

 

Remove the batteries, if you are not going to use the device for a while, to prevent dam-

age from leaking batteries since even leak proof batteries may corr ode. Only handle leak-

ing or corroded batteries with suitable protective gloves. Risk of acid burns.

 

Do not leave batteries lying around carelessly. They might be swallowed by children or 

pets. If swallowed, consult a doctor immediately.

 

Make sure that the batteries are not short-circuited. Do not throw batteries into a fire. 

 

Batteries (non-rechargeable) must not be recharged. There is danger of explosion.

To insert/replace the batteries proceed as follows:
Disconnect the device from the mains socket and remove all connected cables.
Remove the two rear screws from the battery compartment. Remove the lid carefully.
Insert two new button cells of the same type into thebattery com-

partment, paying attention to the correct polarity. The plus pole 

of both batteries should points outwards. 
Close the battery compartment and screw back in place.

Display

The display is divided into three parts in order to show several parameters simultaneously. The selection 

of the parameters for the individual display areas is done with the keys 3, 2 and 9. The grid symbols on the 

keys indicate the display area.  
Each time you press an individual key, the display is switched to the next parameter.
Key 3 switches the display area on the left top,
Key 2 switches the display area on the right top,
Key 9 shifts the display area on the bottom.

+

+

Summary of Contents for 125417

Page 1: ...ge werblichen Berufsgenossenschaften für elektrische Anlagen und Betriebsmittel zu beachten Das Gerät erwärmt sich bei Betrieb Achten Sie auf eine ausreichende Belüftung das Gehäu se darf nicht abgedeckt werden Wenn anzunehmen ist dass ein gefahrloser Betrieb nicht mehr möglich ist so ist das Gerät außer Betrieb zu setzen und gegen unbeabsichtigten Betrieb zu sichern Es ist anzunehmen dass ein gef...

Page 2: ...romaufnahme Max gemessene Stromaufnahme Wirkleistung 230 25 6 20 V W TOTAL kWh 230 48 6 20 V W TOTAL kWh MAX 230 3000 6 20 V W TOTAL kWh OVERLOAD 230 0 50 6 20 V TOTAL kWh FORECAST DAY 230 0 06 6 20 V TOTAL kWh A 230 0 208 6 20 V TOTAL kWh MAX A Für die Anzeige der Kostenvorschau muss ein Stromtarif eingestellt sein und das Messgerät muss mind 24 h eine Messung durchführen Die Daten werden alle 24...

Page 3: ...al workers society for electrical equipment and utilities must be followed Since the device generates heat when in use ensure there is sufficient ventilation provided do not cover the housing If you have a reason to believe that the device can no longer be operated safely disconnect it immediately and secure it against being operated unintention ally It can be assumed that safe operation is no lon...

Page 4: ...mption effective power 230 25 6 20 V W TOTAL kWh 230 48 6 20 V W TOTAL kWh MAX 230 3000 6 20 V W TOTAL kWh OVERLOAD 230 0 50 6 20 V TOTAL kWh FORECAST DAY 230 0 06 6 20 V TOTAL kWh A 230 0 208 6 20 V TOTAL kWh MAX A In order to display the cost estimates the electricity tariff must be set and the meter must complete a 24 h reading The data is updated every 24 h If these requirements are not met 0 ...

Page 5: ...elatives aux installations et aux matériels électriques des associations profession nelles L appareil chauffe durant le fonctionnement Veillez à assurer une ventilation suffisante Le boîtier ne doit pas être recouvert Lorsqu un fonctionnement sans risques de l appareil ne semble plus assuré mettez le hors service et veillez à ce qu il ne puisse plus être remis en service involontairement Une utili...

Page 6: ... la touche SET intensité absorbée intensité absorbée maxi mesurée puissance active 230 25 6 20 V W TOTAL kWh 230 48 6 20 V W TOTAL kWh MAX 230 3000 6 20 V W TOTAL kWh OVERLOAD 230 0 50 6 20 V TOTAL kWh FORECAST DAY 230 0 06 6 20 V TOTAL kWh A 230 0 208 6 20 V TOTAL kWh MAX A Pour l affichage de la prévision des coûts un tarif du courant doit être fixé et l appareil de mesure doit effectuer une mes...

Page 7: ...živnostenských profesních sdružení pro elektrická zařízení a provozní prostředky Přístroj se při provozu zahřívá dbejte na dostatečné větrání plášť se nesmí zakrývat Pokud lze předpokládat že již nebude možný bezpečný provoz pak je třeba přístroj vypnout a zajistit proti nechtěnému provozu Je třeba předpokládat že bezpečný provoz již nebude možný pokud jsou na přístroji viditelná poškození přístro...

Page 8: ...n max naměřený výkon hranice alarmu W nebo A rozpočet nákladů přepínání dne měsíce roku se provádí tlačítkem SET příkon proudu max naměřený příkon proudu činný výkon 230 25 6 20 V W TOTAL kWh 230 48 6 20 V W TOTAL kWh MAX 230 3000 6 20 V W TOTAL kWh OVERLOAD 230 0 50 6 20 V TOTAL kWh FORECAST DAY 230 0 06 6 20 V TOTAL kWh A 230 0 208 6 20 V TOTAL kWh MAX A Pro zobrazení výhledu nákladů musí být na...

Reviews: