SaniDry XP CONDENSATE PUMP INSTALLATION INSTRUCTIONS

STEP 1: 

The condensate pump kit 

includes: 25' drain hose, drain hose clamp, 
condensate pump, two mounting screws and 
instructions.

STEP 4: 

Pull discharge hose out of unit until it 

stops. Cut the condensate drain hose at a 45° 
angle approximately 10 inches from the unit.

STEP 7: 

Insert the drain hose into the 

condensate pump reservoir as shown.

STEP 2: 

Predrilled mounting holes are located 

near the bottom and on the same side of the 
unit as the drain hose.

STEP 5: 

Example of hose cut at a 45° angle. 

The angle prevents the hose from sealing tight 
against the bottom of the pump reservoir.

STEP 8: 

Install the provided drain hose over the 

condensate pump nipple. Tighten hose clamp.

STEP 3: 

Secure the condensate pump to the 

unit with the two provided screws.

STEP 6: 

Remove the plug as shown.

STEP 9: 

Route the condensate pump drain hose 

to an appropriate drain and plug the condensate 
pump into a standard 115VAC outlet.

9

SaniDry XP Installer’s & Owner’s Manual

Summary of Contents for SD109 SaniDry XP

Page 1: ......

Page 2: ...the Sensors 5 8 8A Coil Sensor 5 8 8B Humidity Sensor 5 9 Other Functions 5 9 1 Control Lock 5 9 2 Display Coil Temperature 5 10 Electromagnetic Compatible Standard 5 10 1 EMS Criteria 5 10 2 EMC Crit...

Page 3: ...om Pressurization assures that open combustion devices do not backdraft This can be accomplished by installing a duct from the humid room to the SaniDry XP inlet and by allowing the SaniDry XP to disc...

Page 4: ...in the mode previously selected 7 OPERATING MODES 7 1 POWER UP When the unit is powered up it will be in STANDBY MODE indicated by the flashing RED RUN LED All other LEDs are extinguished None of the...

Page 5: ...DEFROST CYCLE every 53 minutes of operation 8 8B HUMIDITY SENSOR When the humidity sensor s output voltage is less than 0 5V or more than 4V the control unit considers it faulty and will display E2 i...

Page 6: ...efrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the...

Page 7: ...porator 1 SS 0 6mm 31 Tubing evaporator 1 9 52mm OD x 8mm wall copper tubing 32 Grommet 1 Buna N 33 Capillary 2 2 5mm OD x 1 0mm wall 34 Tubing discharge 1 6 35mm OD x 8mm wall copper tubing 35 Filter...

Page 8: ...SaniDry XP SERVICE PARTS LIST To order contact your local Basement Systems Dealer 8 SaniDry XP Installer s Owner s Manual Exploded View...

Page 9: ...edrilled mounting holes are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealing tight against t...

Page 10: ...x and bend the tabs in 6 Place the collar over the blower outlet and line up the tabs with the holes in the cabinet 7 Using 4 screws from the kit attach the collar to the unit collar Ductable Inlet Ex...

Page 11: ...nty claim to BSI such that BSI receives such claim prior to the end of the applicable warranty period BSI shall have no obligation hereunder with respect to any claim received by BSI after the expirat...