Attaching the FlowStation Module 

1.  Make sure the power cable is untangled and 

routed around the top of the module.  

2.  On the middle of the three attachment 

points  for the FlowStation module (directly 
above the capacitor on the control board), 
put a washer on one of the stainless steel 
screws, and then partially thread the screw 
into the standoff.    

3.  On the mounting plate attached to the 

back of the FlowStation module, find the 
V-shaped notch. Align that notch with the 
screw that you inserted in step 2.  

4.  Align the other two holes on the mounting 

plate with the upper attachment points and 
partially thread a stainless steel screw into 
each hole.  

Tip

: To put the screws in these hard-to-reach 

locations, you might want to use a magnetic 
screwdriver. 

5.  Verify that the screw with the washer is 

securely seated in the V-shaped notch on 
the mounting plate, and then tighten the 
two screws at the top of the FlowStation 
module. 

6.  Attach the FlowStation power cable to 

the connector on the right side of the 
BaseStation 3200 control board.  

7.  Tuck the extra power cable length under 

the FlowStation module. 

Summary of Contents for FlowStation

Page 1: ...the pedestal at the factory The following instructions describe the steps for installing the add on module into a pedestal that is already in service Required Tools You will need a Phillips head screwdriver Shutting Down Power to the Pedestal 1 On the BaseStation 3200 turn the dial to the Off position 2 Open the lower door on the pedestal and locate the on off key on the power box 3 Remove the scr...

Page 2: ...eft wall remove the nuts on the lower edge of the external antenna assembly and then remove the screws Set the nuts aside to be reused later 4 Align the holes on the Ethernet switch mounting plate with the holes on the inside wall of the pedestal Note The photo on the right shows a cell modem module on the mounting plate with the Ethernet switch The cell modem module may not be present in your con...

Page 3: ... shows the dust cover removed from the control board You may not need to remove the cover to access the 5 pin connectors 3 Carefully remove the plug from the lower connector 4 Attach the 5 pin splitter onto the lower connector 5 Attach the plug that you removed from the control board onto one of the connectors on the 5 pin splitter 6 Attach the end of the power cord from the Ethernet switch to the...

Page 4: ...the FlowStation module find the V shaped notch Align that notch with the screw that you inserted in step 2 4 Align the other two holes on the mounting plate with the upper attachment points and partially thread a stainless steel screw into each hole Tip To put the screws in these hard to reach locations you might want to use a magnetic screwdriver 5 Verify that the screw with the washer is securel...

Page 5: ...n modules 5 In another Ethernet port connect an Ethernet cable to the Ethernet wall jack if needed Turning the Power On 1 Remove the screw that fastens the key to the box IMPORTANT Put the screw in a safe place because you will need to replace it later 2 Insert the key into the on off switch and press it up to turn the power on 3 Remove the key and reattach it with the screw to prevent it from bei...

Reviews: