BL-FLOWSTN-P FlowStation Module
Installation Guide
1-866-294-5847
Rev 10.26.2016
www.baselinesystems.com
Ethernet Switch Mounting Instructions
1. Before proceeding, verify that the power is off. The LEDs on the BaseStation 3200 faceplate
should not be illuminated.
2. Move the Ethernet radio module out of the way:
Remove the screws used to mount the Ethernet radio module to the back wall. You
may be able to move the Ethernet radio module toward the center of the pedestal
without disconnecting the power and antenna cables. If not, remove the power and
antenna cables, and then set the Ethernet radio module aside in a clean location.
3. On the inside left wall, remove the nuts on the lower edge of the external antenna assembly,
and then remove the screws. Set the nuts aside to be
reused later.
4. Align the holes on the Ethernet switch mounting plate with
the holes on the inside wall of the pedestal.
Note
: The photo on the right shows a cell modem
module on the mounting plate with the Ethernet
switch. The cell modem module may not be present in
your configuration.
5. Locate the 2 long screws that were provided
with the Ethernet switch. Working from the
outside of the pedestal, push the screws
through the holes on the pedestal wall and
through the holes on the Ethernet switch
mounting plate.
6. Thread the nuts onto the screws and tighten
them.
7. Replace the Ethernet radio module and
reconnect the power and antenna cables if
necessary.
8. Continue with the
Power Connector
instructions on the next page.