Follow Local Electrical Codes and Practices
Zone Terminals
Common
Terminals
Sensor Terminal
See “Burying the
biSensor” details in
the biSensor Install
Guide
DBR/Y-6 or equivalent
moisture-resistant
connectors
Use wire nuts to test communication,
and then replace with Baseline approved
moisture-resistant connectors before
burying.
Sensor Terminal
biSensor Installation Instructions
1. Install the biSensor near the closest valve location. Follow the “Burying the biSensor” instructions
included with the biSensor.
2. Connect the red wire from the biSensor
to the power wire or pilot wire of the valve and black wire from
the biSensor to the common wire of the solenoid using the provided 3M™ DBR/Y-6 or equivalent
moisture-resistant connectors. It is critical that polarity be maintained.
3. Connect the pilot wire from the valve to either the A1, A2, B1, or B2 terminals on the controller.
4. Press the biSensor update button and verify that the light above the terminal (A1, A2, B1,or B2) stays
on.
5. Assign the biSensor and test its operation according to the instructions in the controller’s user manual.