background image

absolute zero and alternate (relative) zero

absolute zero mode: 

when in absolute zero mode, there is no 

REF

icon on LCD. If 

REF

icon is

present, short press 

on / off / alternate zero 

button to enter absolute zero mode. LCD displays

angle of absolute horizontal level. If unit is rotated clockwise from absolute zero a + sign is pres-

ent in front of values. If unit is rotated counterclockwise from absolute zero a - sign is present.

For absolute (horizontal zero) measurement, put the unit near the joint needed to be measured.

The inclinometer shows the angle between the inclinometer plane and the horizontal plane. Allow

the reading to settle before noting the angle.

alternate (relative) zero mode: 

Setting an alternate reference point allows you to set any angle

to ZERO. This new ZERO is now a reference point from which to take measurements. For in-

stance, you may want a surface that is actually 25° off absolute zero (horizontal) displayed as

ZERO so you can measure all other angles relative to that benchmark. See the example below

for Relative angle measurement:
1. If the unit is in absolute zero mode, the 

REF

icon will not appear on the LCD. Put the incli-

nometer on the surface that is actually 20° off the horizontal plane. The unit reads 20°.

2. Press the 

on / off / alternate zero 

button to toggle to alternate zero mode (the icon 

REF

is now

visible and the angle readout is now ZERO).

3. Put the inclinometer on the surface that is actually 30° off the horizontal. The “10.0°” shown

on the display is relative to the 20° off the horizontal plane.

REF

icon is

visible

This angle readout is 20° in 

absolute zero mode

This angle readout is 0° in

alternate zero mode

This angle readout is 10° in

alternate zero mode

Change to

relative measurement

mode by pressing 

alternate zero

button

Horizontal plane

Operating Instructions:

NOTE:

If the unit has been dropped, follow calibration and set-up instructions on following page.

on / off / alternate zero button

Press once to turn the LCD display screen on. Press the button again to toggle the screen meas-

urement between absolute zero and alternate (relative) zero mode. 

REF

icon displays when unit

is operating in alternate zero mode. Long press to turn off the LCD.

hold button

If you want to lock the reading while performing a measurement, simply press the 

hold 

button

once the measurement settles. The angle reading will freeze and you can record the reading. An

H

icon will appear on the LCD. You can cancel this function by pressing the 

hold

button a sec-

ond time. You will now be viewing live angle measurements. 

Note

: changing from relative to ab-

solute zero mode cannot be done when the 

H

icon is visible.

light button

Press once to open / close the back light.

+

-

Appearance and technical data

hold

on / off / 

alternate zero

battery

compartment

screw-holes for leveling feet

measuring range

0~360°

resolution

0.1°

accuracy

+/- 

0.5°

power

DC3V (AAA x 2)

battery life

100 hours continuous

working without back-light

working temperature

-10°C to 50°C

working humidity

<85%

transportation and storage

temperature

-20°C to 70°C

IP level

IP65

low battery indicator

battery sign flashing when

voltage below 2.2V

LCD screen icons

Replace batteries when the Battery Power icon is flashing. Only flashing when voltage below 2.2V.
Indicates that the inclinometer is measuring in alternate zero (relative) mode.
This icon appears on the screen when the HOLD function is activated.
Indicates that the inclinometer is calibrated for one direction.
Indicates that the inclinometer is calibrated for another direction

Calibration

The digital inclinometer has been pre-calibrated at the factory. The product should only be recali-

brated if it has been dropped. (see steps below)

1. Place the unit on a flat horizontal surface, press 

hold

button and 

on / off / alternate zero

but-

ton at the same time. The calibration mode is activated and a “-1” will be displayed.

2. Press 

on / off / alternate zero

button again, “-1-” will flash briefly. Do not move unit until “-2-”

displays.

3. Rotate unit 180 degrees in the same location and press 

on / off / alternate zero

button, “-2-”

will flash briefly. Do not move until the unit has completed the calibration and reset the display

to the current level.

calibration complete

start calibration

Reviews: