Adjusting the Timing Control   

(Factory set to run for approximately 30 seconds after float ball drops): 

 

Use sketch to guide you and the marking on the end of the knob as a 
guide. Control is located on bottom of Ejector and has the small tube 
coming out of it connecting to the small “Tee” on the top of the Ejector.  

 

Pump stops too soon:

 ¼ Turn Timing Knob right (clockwise) to produce 

a 15 Second Longer Run Time. If you close it completely, pump will not 
shut off.  

 

Pump runs too long:

 ¼ Turn Timing Knob left (counter-clockwise) 

produces a 15 Second Shorter Run Time. If you open it too far, pump may 
run for too short a time to be effective.  

 

If you lose your place

 

and must start over:

 Turn the Timing Knob all 

the way in to the right (clockwise) and then back to the left (counter-clockwise) 1 ¼ Turn. This is the factory setting. 

 

30 - 45 seconds run time after the float drops is a good average 

“rule-of-thumb”. Running it dry will not harm it, but it 

does use water unnecessarily when this happens. 

 

This backup sump pump is to be tested to ensure proper operation at least 3-4 times per year. 
Lift the float by hand and confirm pumping, runtime, and automatic shut-off. Record the date 
after each test. 

Place these instructions back into the plastic bag they came in 

and keep them near the pump. 

 

30 Day Customer Satisfaction Guarantee

 

Within 30 days of purchase, if you are not completely satisfied with your new Water Powered Backup Sump Pump, it must be returned 
in its original packaging, unused, and in re-salable condition. The Company will then refund your money, in full, excluding shipping 
charges. If returned in 31-90 days after purchase, a 15% Restocking Charge will be applied. No returns accepted after 90 days. Please 
contact the dealer where you purchased your pump to obtain refund. If purchased directly from The Company, you must call our 
Customer Satisfaction Department at 800 554 1426 to process return or to receive Technical Assistance. Please give your name, 
address, phone number, date of purchase, and model number

Five Year Limited Warranty 

Base Products Corporation (the “Company”) warrants the Basepump (the “Product”) against defects in material and workmanship for a 
period of Five Years from the date of the shipment. In the event of any defect within the warranty period, the Company will, at its option, 
replace or recondition the Product without charge providing the Product is returned, prepaid to our offices in Buffalo, New York. The 
replacement or reconditioning of the Product shall constitute the exclusive remedy for any alleged defect.  
 
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR 
REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR, OR THE SHORTEST PERIOD 
ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. THE LIABILITY OF THE COMPANY SHALL NOT IN ANY CASE EXCEED 
THE COST OF REPLACEMENT OF THE PRODUCT, AND IN NO CASE, SHALL THE COMPANY OR ANY OF ITS DISTRIBUTORS 
BE LIABLE FOR ANY INCIDENTAL, INDIRECT, CONTINGENT OR CONSEQUENTIAL LOSS OR DAMAGES SUCH AS PROPERTY 
DAMAGE OR EXPENSES RESULTING FROM THE FAILURE OF THE PRODUCT, DELAYS, LOSS OF USE, NEGLIGENCE, 
DAMAGE FROM PECULIAR WATER CONDITIONS, CHEMICALS OR FOR BREACH OF THIS OR ANY OTHER WARRANTY, 
EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT. THE 
COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, EXCEPT AS PROVIDED IN THIS LIMITED WARRANTY. 
THIS WARRANTY BECOMES VOID BY ANY MISAPPLICATION, MISUSE, ABUSE, OR IMPROPER INSTALLATION OF THE 
PRODUCT. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY 
VARY FROM STATE TO STATE. WARRANTY IS APPLICABLE IN THE USA AND CANADA, ONLY.

   

 

This warranty does not cover defects in the Product resulting from: (a) abuse or mishandling of the Product; (b) modification, alteration, 
repair or service of the Product by anyone other than Base Products Corporation; (c) improper or neglect in maintenance. This warranty 
does not cover any water damages caused by defects in the Product as such defect should have been identified during periodical 
testing.  The owner's use of these Products confirms the understanding that these Products 

do not constitute an insurance policy 

and they are only loss mitigation products used to reduce the risk of water damage, however not eliminating such risk. 
 
The above warranty may not be altered except in writing signed by both parties hereto.  

 

Summary of Contents for RB750

Page 1: ...e If absolutely necessary may be used on RB750 only Note If using tubing RB750 only use a x reducer 4 Pipeline Restrictions Pump should be teed in before these devices that restrict water flow stop waste valves globe type valves and some Pressure Regulator Valves PRV Basepump MUST tee in before water softeners conditioners and or water filters Water meter must be minimum 5 8 or 3 4 standard Averag...

Page 2: ...C Check Valve 3 PVC Exit Unit with Internal Diffuser Disk 4 2 Clip on Hangers 5 Polypro Male Adapter 1 Float Assembly 2 12 Feet of Transfer Tube 3 5 Cable Ties 4 6 Clear tube To be used in Step 5 Parts Kit Water Alarm Kit 1 3 Wood Screws 2 Clip on Hanger for Suction Pipe 3 Suction Screen with PVC Adapter 4 2 Hose Clamps 3 Feet of Discharge Hose not shown 1 Alarm Battery 2 Mounting Bracket Screw 3 ...

Page 3: ...000 Male threaded Suction and Discharge Opening 1 1 4 socket CB1500 1 or Male threaded Suction and Discharge Opening 1 1 2 socket Water service requirements Minimum pressure 40 lb PSI Maximum pressure 90 lb PSI Minimum City Water Flow Rate RB750 7 GPM HB1000 10 GPM CB1500 15 GPM Back flow Prevention Check with your local plumbing or water department for their requirements regarding back flow preve...

Page 4: ...pendicular to exterior wall with discharge turned at an angle Under Joist Outdoor Discharge Basepump mounted under ceiling joist with Discharge hose sloping upward and out Suction Pipe Options Pump does not need to be directly above the sump in case of an obstacle such as a heat duct electrical panel window stairway etc Horizontal distance up to 10 Feet across Shared discharge with Primary Pump Yo...

Page 5: ...e to the proper length cement the upper end into the Ejector check valve making sure that the lower end of the Suction Screen is approx 2 4 inches above the bottom of the sump Either 45 or 90 degree elbows maybe used to offset the suction pipe if necessary See page 4 Suction pipe may be fastened to the side of the sump if necessary using the gray clamp included in the parts kit ___________________...

Page 6: ...ed to a security system or auto dialer Operation When the float is up the alarm sounds and the relays close When float drops the alarm will silence and the relays will open Start Up Procedure Open the water shut off valve and check for leaks Note Pump may turn on at this time so be sure the discharge piping is completed Lift the float ball for 10 seconds to release air trapped in the Ejector and T...

Page 7: ...ter supply to the pump and remove the tube from the top of the Float Assembly PUSH in the plastic ring while you PULL out the tube Point the end of the tube into the sump and turn the water on to the pump If water shoots out of the tube and the pump turns on then it appears the float is the problem Call the factory for support and or replacement If no water comes out check the other end of the Tra...

Page 8: ...rrants the Basepump the Product against defects in material and workmanship for a period of Five Years from the date of the shipment In the event of any defect within the warranty period the Company will at its option replace or recondition the Product without charge providing the Product is returned prepaid to our offices in Buffalo New York The replacement or reconditioning of the Product shall ...

Reviews: