background image

4

Do

 not place directly on vapor barrier. For example, use blocks, or pavers to create a level surface.

NOTE: AirWerx 55 Dehumidifiers can't sit directly on the floor unless the unit is feeding directly into a 
sump pump next to it. Elevation is required to allow gravity flow of condensate water drain.

If the unit is handled in such a manner that the compressor did not remain in the upright position, it is 
necessary to place on a level surface and wait a minimum of 2 hours before turning the unit "on".

Step

 #

1

Place

 

dehumidifier

 

on

 

a

 

level

 

surface

.

 

The

 

drain

 

line

 

should

 

be

 

routed

 

to

 

a

 

suitable

 

drain

 

on

 

the

 

outside.

 

It

 

must

 

flow

 

down

 

to

 

a

 

drain

 

without

 

any

 

loops,

 

dips,

 

or

 

valleys.

Step #2: Set Up Drain Line

(

Note:

 

Keep

 

the

 

length

 

of

 

PVC

 

drain

 

pipe

 

to

 

a

 

minimum

)

.

5

Always

 

test

 

the

 

drain

 

before

 

leaving

 

the

 

installation

 

area

.

4.

 

Support

 

the

 

PVC

 

tubing

 

so

 

that

 

it

 

maintains

 

a

 

smooth

 

downward

 

flow

 

to

 

drain.

2.

 

Insert

 

PVC

 

into

 

a

 

3

/

4

elbow,

 

then

 

attach

 

to

 

a

 

3

/

4

OD

 

length

 

of

 

PVC

 

to

 

drain.

3.

 

Insert

 

the

 

open

 

end

 

of

 

the

 

tubing

 

into

 

the

 

3

/

4

pipe

 

so

 

that

 

it

 

does

 

not

 

extend

 

into

 

the

 

elbow

 

fitting.

 

For

 

proper

 

flow,

 

a

 

minimum

 

downward

 

slope

 

of

 

1

per

 

10'

 

runs

 

is

 

required.

 (

Note:

 

If

 

a

 

proper

 

downward

 

angle

 

is

 

not

 

possible,

 

then

 

it

 

is

 

recommended

 

to

 

use

 

an

 

AirWerx

 

90X

 

which

 

includes

 

an

 

integrated

 

pump.

 

Alternatively

you

 

can

 

use

 

an

 

external

 

condensate

 

pump

)

.

1.

 

Cut

 

a

 

piece

 

of

 

3

/

4

OD

 

PVC

 

that

 

is

 

approx.

 

6

long.

Recommended

 

Drain

 

Option

-

Transition

 

to

 

PVC

 

Pipe

Drain Tube - 12 inches Long. 19mm OD.

Summary of Contents for AirWerx 55

Page 1: ...Tel 1 888 641 8862 Web www baseaire com E mail sales baseaire com Installation Operations Manual AirWerx 55 Patented Specifications subject to change without notice...

Page 2: ......

Page 3: ...inciple of Operation Installation Key Functions Indicator Lights Remote Control Operating Instructions Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshooting Spare Parts Warranty...

Page 4: ...d repaired by a qualified technician AirWerx Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level Operating the unit in any other orientation could a...

Page 5: ...o grounded electrical circuit 3 Do not use an extension cord 1 Disconnect electrical power before servicing 4 Do not use a plug adapter Principle of Operation The AirWerx Series Dehumidifier utilizes...

Page 6: ...to a drain without any loops dips or valleys Step 2 Set Up Drain Line Note Keep the length of PVC drain pipe to a minimum 5 Always test the drain before leaving the installation area 4 Support the PV...

Page 7: ...idity levels displayed are approximate only 5 3 Continuous Mode To switch into continuous mode simply use the down arrow to set the humidity below 35 The Cont light should illuminate green on the disp...

Page 8: ...humidifier is installed in your crawl space the remote could be mounted in your living space or garage This provides you with an easy way to monitor the dehumidifier Remote Control Instructions 1 Humi...

Page 9: ...own arrow buttons to adjust the humidity level 1 On o power button 2 Up Button Down Button Use the Mode button to switch between dehumidi cation and a ducted application 3 Mode The symbol on the displ...

Page 10: ...ide out the filter 3 Clean the filter mesh by vacuuming or washing with warm water no soap or solvents 4 Be sure filter is completely dry before restarting the unit Coil Maintenance Once per year clea...

Page 11: ...ie wrap Also keep in mind that the supply ducting can be screwed into an adapter if necessary Ducting Installation Maximum length for ducting 6 Note The supply duct adapter is standard on all units Re...

Page 12: ...el Move the dehumidifier to flat firm ground Clean the filter mesh according to instructions listed in manual The unit is outside the operating temperature range Modify the room conditions so the temp...

Page 13: ...ble Supply Duct 72 Main Control Board Display Board RH Temperature Sensor A 501 A 502 A 503 A 504 A 505 A 506 A 508 A 509 A 510 A 513 A 517 A 518 A 519 Fan Motor Complete Fan Assembly Fan Capacitor Co...

Page 14: ...omers are not available 1 Once receive the goods customers must log in www baseaire com to fill out the warranty Registration form and submit to BaseAire company We will receive your purchasing and in...

Page 15: ...y fraud or attempted fraud FILTERS RUBBER PARTS POWER CORDS The foregoing shall constitute the total liability of seller in the case of defective performance of all or any of the equipment or services...

Page 16: ...Scan QR Code to Register Warranty...

Reviews: