background image

10

Normal use of the water pump

1.  

To verify if the drain bu

tt

on is func

ti

onal.

Gravity Drainage

Use of gravity drainage pipe (gravity drainage or pump drainage can

be selected according to the working environment)

Gravity Drainage

Drain

Maintenance and application

of water pumps

When the power is on, press the drain bu

tt

on. If the collected moisture is properly drained 

through the water tray nozzle, this indicates that the condensate pump is not defec

ti

ve.

Water Pump Drainage

2.  

To verify if the automa

ti

c drain system is func

ti

onal.

When the dehumidifier automa

ti

cally ac

tivat

es the pump a

ft

er a certain amount of moisture 

is collected, this indicates that the float switch is working properly.

3.  

Pump Error.

In the event of a pump failure, the screen will display a “E4” Error code to stop the 

dehumidifier from running to prevent water leak.”

When the gravity drain system is in use, elevate the unit from the ground. This can be done 

by  hanging  the  dehumidifier  on  the  floor  joist  or  using  a  level  object  to  place  the 
dehumidifier  on.  Failure  to  elevate  the  unit  higher  than  the  drain  pipe  will  result  to  a 
water leak.

Summary of Contents for AirWerx 35P

Page 1: ...AirWerx35P Installation OperationsManual Web www baseaire com E mail sales baseaire com Specificationssubjecttochangewithoutnotice Tel 1 888 641 8862...

Page 2: ...Operation 4 Installation 4 Key Functions 6 Indicator lights 6 Remote Control 8 Diagram 8 Maintenance 8 Dehumidifier Storage 9 Troubleshooting 10 Maintenance and application of water pumps 13 Spare Pa...

Page 3: ...ier should be maintained and repaired by a qualified technician The AirWerx 35P dehumidifier is intended for operation when the unit is standing and horizontal only Operating the unit in any other dir...

Page 4: ...it protector 15 amps To reduce the risk of injury Warning 240 volts AC power may cause serious injury due to electric shock 1 Disconnect the power supply before servicing 2 Only plug the device into a...

Page 5: ...ifier on a level block or paver Wait for at least 12 hours before turning on the dehumidifier after delivery Step 2 Set up the drain line Remove the nut from the drain nozzle before connecting the dra...

Page 6: ...dehumidifier to properly use this drain system This allows the dehumidifier to continuously drain the moisture collected If a high level of water is detected by the float switch for 14 seconds the scr...

Page 7: ...r is set to continuous operation mode In continuous mode of operation this light is always on other states this light is off 4 Water Pump Drainage Water pump mode this light is on gravity drainage mod...

Page 8: ...nuous mode cont will appear on the display to indicate continuous mode 6 Drain Pump P Press this button to drain or pump the collected moisture or water out of the dehumidifier NOTE The above symbol w...

Page 9: ...ol port A1 A6 auxiliary terminal interface Maintenance Cleaning the body Use a soft damp cloth to clean the exterior of the unit Do not use any soap or solvent Coil Maintenance Once a year clean coils...

Page 10: ...al Trouble code E 1 E1 Humidity sensor lssues Checkthewireconnectionsatbothends Iftherearenovisibleproblems the sensormaybefaulty Trouble code E 4 Water Pump Failure Confirmwhetherthepumpismalfunction...

Page 11: ...Water Pump Drainage 2 To verify if the automatic drain system is functional When the dehumidifier automatically activates the pump after a certain amount of moisture is collected this indicates that...

Page 12: ...e hose is blocked by foreign objects or bent and deformed 2 The drainage height exceeds the standard 3 Water level switch failure 4 The water pump is malfunctioning or its service life has expired 5 T...

Page 13: ...ater pump panel and you can see the fixed status of the water pump 2 Use a Phillips screwdriver to unscrew the screw of the pump fixing bracket 3 Pull out the hose fixed in the water reservoir and tak...

Page 14: ...610 S 611 MERV 1 Filter S 612 AirWerx 35P Filter Remote Control Kit cable remote control Main Control Board Display Board Temperature and Humidity Sensor BlowerMotor Air Duct Set Fan Capacitor Compres...

Page 15: ...with the product for operation installation and maintenance Baseaire will not provide home service during or after the warranty period You may be responsible for shipping costs to bring the product t...

Page 16: ...15...

Page 17: ...dress City State Zip Phone E mail If you have any questions please feel free to contact us at 888 641 8862 or visit www baseaire com Register your unit for warranty using this link https www baseaire...

Page 18: ......

Reviews: