background image

Installation Manual

FIBONACCI RS485

©

 202

1

bas

alt

e v1.1

basalte 

bv

 

  |   hundelgemsesteenweg 1A   |   9820 merelbeke   |   belgium

t +32 (0)9 385 78 38   |   f +32 (0)9 329 66 95   |   www.basalte.be   |   [email protected]

Technical data

Current consumption:

   Peak during startup: 1 W

 

                               During operation: 0,5 W

Ambient temperature:

 Operations between 5 & 45°C

                                         Storage & Transport between 15 & 55°C

 Max.  humidity:

 93% relative humidity - no moisture condensation

Protection Class:

 II

Type of protection:

 IP20

Certification: 

CE

Installation

1. Rough-In

Use a standard 1-gang US wall box or a standard European back box.
The included mounting bracket should be mounted on the wall using the included screws.

2. Installing Fibonacci on the wall

Position Fibonacci for portrait mounting, align the mounting bracket
hooks with the Fibonacci mounting slots and gently press it towards
the mounting bracket/wall. Fibonacci snaps in when pushed to its 
mounting bracket.

Powering up Fibonacci

Connect the 4 colored strands to the RS485 bus cable in accordance 
to standard RS485 guidelines.
Please refer to the software manual to configure Fibonacci.

Removing Fibonacci

Follow the step 1 and 2 in order to remove Fibonacci from the wall.

 

1

2

Single-gang box

Mounting

bracket

Dry wall

Push

Pull

a   60 mm (2,36”)

b   84,5 mm (3.33”)

a

b

 

Only use the openings on the vertical axis as shown on the picture.

 

Don’t screw on the mounting bracket too hard, to avoid bending. This would hinder   

 

proper snapping-in of the keypad.