Installation Manual
ASANO A3
© 2014 basalt
e v1.0
How to install
1
Connect to the
CobraNet
Connect the Asano A3 to the CobraNet network using
Ethernet (CAT5e) cable.
CobraNet is configured using ETS
2
Connect the
input sources
• Source 1 : analogue input using RCA connector
• Source 2 : digital input using S/PDIF connector
3
Digital output
- Zone 1
An external amplifier can be connected using the digital
S/PDIF output (zone 1). The amplifier can be switched
on and off using the 12V trigger output.
4
Analogue output
s - Zone 2 & 3
The two analogue zones are connected with RJ45, which is
compatible with B&O Powerlink. The RJ45 outputs can also
be converted to standard RCA connectors using the optional
A3 Audio Splitter (718-01)
. The A3 splitter has a separate
trigger output to switch on and off the amplifier.
IMPORTANT:
Shielded/Foiled twisted pair (S/FTP), such as
Cat.7, should always be used to connect the analogue zones
to the Asano A3.
5
KNX bus
Connection to the KNX bus is made by using the standard
KNX push wire connection
6
Power supply
The Asano A3 has to be powered by a Euro mains power lead
with a 230 V AC input.
To avoid power surges never disconnect the active power
cable at the side of the device .
Technical data
Power:
220V - 240 V AC
Power consumption:
5W
Analogue input sensitivity:
2V RMS
Ambient temperature:
Operation: -5°C to 45°C
Storage: -15°C to 55°C
Transport: -15°C to 55°C
Dimensions:
w 215 x h 40 x d 160 mm
Weight:
1,0 kg
Max. humidity:
93% relative humidity,
no moisture condensation
Protection class:
II
Type of protection:
IP 20
Certification:
CE
basalte bvba | hundelgemsesteenweg 1A | 9820 merelbeke | belgium