Possible Malfunctions
16 / 19
100083
EN
Error
Possible Cause
Solution
The water tank if
filled, but the 'ADD
WATER' indicator
light it lit.
Water is not pure, or there
are foreign objects in it.
Fill with fresh drinking
water.
The filter in the bottom tank
underneath the storage
container is clogged.
Clean the water filter.
Water flows out of
the water drain at the
rear wall of the
appliance.
The water drain is
obstructed.
Clean the water drain.
The appliance does
not start the ice
production.
The water is not pure
enough.
Fill with fresh drinking
water.
The wall of the bottom tank
underneath the storage
container is dirty.
Clean the bottom tank.
Ice cubes are brittle.
Ambient temperature too
high.
Press and hold the
ON/OFF switch for 5
seconds. The ice cubes
production cycle will be
extended.
Ice cubes are not
being produced.
The ambient temperature or
water temperature in the
bottom tank is too high.
The appliance should be
used in an environment
with ambient temperature
up to 32 °C and with cold
water in the water tank.
Coolant is leaking.
Contact the service
company.
A tube obstructed in the
cooling system.
Contact the service
company.
The following phenomena are not malfunctions:
– During normal operation, a sound of water flowing is heard. This is a
sound of coolant flowing through the installation.