- 31 -
7. Possible Malfunctions
Problem
Cause
Solution
No cooling
•
Power cable improperly
connected
•
Safety fuse has been
activated.
•
Power outage
•
Damaged temperature
regulator.
•
Remove plug and connect it
again.
•
Check safety fuse, check
the device by connecting it to
another socket.
•
Check the power supply
•
Contact a sales agent
Weak cooling
•
Heat source too close or
device exposed to direct
sunlight.
•
Poor air circulation in the
device.
•
Temperature set
improperly.
•
Device is overfilled.
•
Ensure sufficient space
between device and heat
source.
•
Ensure sufficient space
between device's walls and
other objects
•
Check settings, set a lower
temperature.
•
Do not overfill device, remove
excess products.
The aforementioned problems are only examples. If these or other problems
appear, turn the device off immediately and stop using it. Ask for help from
qualified specialist personnel in examining and repairing the device.
The following are not examples of damage:
1. The sound of flowing water: this happens during normal use, and results from the
flow of coolant trough the device.
2. Condensation drops on side glass panes are normal when the ambient humidity is
high. Remove the water with a soft, dry cloth.