Never carry or lift the device by the supply cable. 

 

In any case do not open the device housing. In case of 
electrical or mechanical modifications the 

electric shock 

hazard

 will occur. 

 

Do not use any acid agents and make sure no water ingresses 
the device. 

 

Never

 operate the device with moist hands or standing on wet 

floor. 

 

Remove the plug from its socket: 

-

 

when the device is not used, 

-

 

in case of anomalies during operation, 

-

 

before cleaning.

 

 WARNING! Danger of injury! 

To avoid injury, follow the safety instructions below. 

 

 

During the device operation, 

never

 place hands, spoons or 

any other kitchen utensils in the feed chute. They may get 
caught by the sieve, resulting in cuts, broken bones or other 
physical injuries.  

 

The knives in the sieve are very sharp. To avoid injury, do not 
touch them with bare hands.  

 

Do not touch any moving parts of the device.  

 

After switching off the device, the motor remains rotating for 
a few seconds. The device can be opened and its elements 
removed only after coming to a complete stop.  

Summary of Contents for PRO 150137

Page 1: ... Bartscher PRO 150137 Original Gebrauchsanleitung V1 0916 ...

Page 2: ...ackaging and storage 28 3 1 Delivery check 28 3 2 Packaging 28 3 3 Storage 28 4 Technical data 29 4 1 Technical specification 29 4 2 About the juice extractor 29 4 3 Overview of parts 30 5 Installation and operation 31 5 1 Assembly 31 5 2 Installation 33 5 3 Operation 34 6 Cleaning 37 7 Possible Malfunctions 39 8 Waste disposal 40 Bartscher GmbH Franz Kleine Str 28 33154 Salzkotten phone 49 0 5258...

Page 3: ...cessible for anyone carrying out the installation servicing maintenance or cleaning Please keep these instructions and give them to future owners of the device 1 Safety This device is designed in accordance with the presently applicable technological standards However the device can pose a danger if handled improperly and inappropriately All persons using the device must follow the recommendations...

Page 4: ...rsons are under the care of a person responsible for their safety or have received instructions regarding appropriate use of the device Children should be observed to ensure that they are not playing with the device Never leave the device unattended when in use Only use the device indoors This device may only be operated in technically proper and safe condition Prevent access of children to the pa...

Page 5: ...act with heat sources or sharp edges The power cable should not hang over the side of the working surface Ensure that no one can step on or trip over the cable The power cable must not be folded bent or tangled and must always remain fully unrolled Never place the device or other objects on the power cable Do not lay the power cable over carpets or other inflammable materials Do not cover the cabl...

Page 6: ...ies during operation before cleaning WARNING Danger of injury To avoid injury follow the safety instructions below During the device operation never place hands spoons or any other kitchen utensils in the feed chute They may get caught by the sieve resulting in cuts broken bones or other physical injuries The knives in the sieve are very sharp To avoid injury do not touch them with bare hands Do n...

Page 7: ...ishwasher 1 3 Proper use The operational safety of the device is assured only in case of proper use according to the operation manual All technical activities like installation and maintenance must be performed by the qualified service personnel only The juice extractor is designed only for producing fruit and vegetable juices CAUTION Any use going beyond the intended purpose and or any different ...

Page 8: ...d by violation of advice concerning operation and cleaning use other than designed alterations made by user use of inadequate spare parts We reserve the right to make technical changes for purposes of developing and improving the useful properties 2 2 Copyright protection The instruction manual including any texts drawings images or other illustrations is copyright No part of this publication may ...

Page 9: ...r The outer and inner packing material should be removed completely from the device before installation NOTE If you liked to dispose the packing consider the regulations applicable in your country Supply re usable packing materials to the recycling Please inspect the device upon completeness In case any part is missing please contact our customer service center immediately 3 3 Storage Keep the pac...

Page 10: ... lagged XXL feed chute with a diameter of 83 mm significantly improves the process of preparation The big 7 liter pulp container lets you squeeze a lot of juice without interruption When the pulp container fills up just remove it and empty it without a need to disassemble the device The lid of the juice extractor is held by the locking arm with housing which allows if the device is correctly assem...

Page 11: ...r drive 2 Locking arm with housing 9 Control elements 3 Motor base 10 Sieve 4 Plunger 11 Feed chute tray 5 Feed chute 12 Adapter ring 6 Lid 13 Juice extraction nozzle with closure 7 Base with rubber feet 14 Juice bowl 5 1 9 3 14 6 13 12 2 4 10 11 7 8 ...

Page 12: ...int 6 Cleaning Assemble the device according to the drawing on page 30 and the description below Place the motor base 3 on a dry flat surface and ensure easy access to the control elements 9 Press the motor base 3 towards the surface until the base rubber feet 7 cling tightly to the surface Place the juice bowl 14 onto the motor base 3 and position the juice extraction nozzle with the closure 13 a...

Page 13: ...e pin at the motor base with the groove at the bottom of the sieve 10 Then place the lid 6 and remember to properly interlock the protrusions in the lid 6 with the grooves in the adapter ring 12 Place the feed chute tray 11 on the feed chute 5 Position the pulp container 1 below the lid 6 For easy cleaning line the pulp container with the plastic bag Finally push the locking arm with housing 2 abo...

Page 14: ...c Never put the device in a moist or wet area Never place the device on an inflammable surface Do not place the device near open flame electric heaters or other heat source Place the device so that the plug is easily accessible so as to quickly disconneet the device if the need arises Connection DANGER Electric shock hazard The device can cause injuries due to improper installation Before installa...

Page 15: ...e instructions and data included in the table below Thin skinned fruit and vegetables do not require peeling You can clean them gently with a clean sponge to remove any dirt or wax coating Thick skins from e g lemons oranges or pineapples must be removed Fruits with large seeds and stones such as mango and papaya and other stone fruits should have them removed to avoid damage to sieve knives Seeds...

Page 16: ...en the hard one apples This helps make the best juice possible When extracting juice from fresh herbs e g mint or parsley insert them into the juice extractor between pieces of fruits and vegetables to achieve the best effect If there is only a small amount of herbs insert them together with pieces of fruits or vegetables Fruits containing starches banana papaya fig avocado mango etc are difficult...

Page 17: ... the feed chute tray with the ready fruit and vegetables and slowly by small portions push with the plunger in the feed chute in the cover Slide the plunger with a gentle push on the feed chute To maximize the juice extraction move the plunger down slowly If pushed too hard the juice amount will be reduced and the device may be damaged WARNING Hazard of injury Do not push the fruit or vegetables w...

Page 18: ...switch off the extractor with the red switch Wait a few seconds until the motor stops completely Only then unplug the device remove the plug from the socket and disassemble for cleaning WARNING Remember to keep the device unplugged if not in use or in cleaning or when removing or placing its parts 6 Cleaning WARNING Disconnect the device from the power supply unplug before cleaning Never clean the...

Page 19: ...ock the sieve have been removed examine the sieve under a light source WARNING Danger of injury The knives in the sieve are very sharp To avoid injury do not touch them with bare hands o Before reassembly carefully wipe down all the cleaned parts or leave them to dry thoroughly CAUTION Never immerse the motor base in running water or any other liquids do not wash it under running water or in the d...

Page 20: ...ection 5 1 Assembly Contact the sales agent The device vibrates The pulp container is full Due to the sticking pulp the sieve cannot keep proper balance Empty the pulp container Switch the device off and clean the sieve follow the instructions of section 6 Cleaning The motor appears to struggle during operation The pulp container is full Empty the pulp container Pulp is sticking to the lid Switch ...

Page 21: ...t a company which is specialized in waste disposal or just contact the local disposal service in your community WARNING To exclude any abuse and the dangers involved make the waste device unfit for use before disposal For that purpose disconnect device from mains supply and remove mains connection cable from the device CAUTION For the disposal of the device please consider and act according to the...