background image

 

 

 INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE AND USE

 Rev-09 

PM.IE 8-9-1-R-GN-DU-GB-09 

12 

ELECTRIC KETTLES  INDIRECT   

“PM8-9IE..A” “PM1IE..A” “PMRIE..A” “PM9IE..GN”  

3 USE 

AND 

CLEANING 

3.1 

WARNINGS AND HINTS FOR USER 

 

 

This manual contains all the instructions required for a proper and safe use of our appliances. 

 

Keep the manual in a safe place for future consultation! 

 

This appliance is for catering use, hence they must be used only by trained kitchen staff. 

 

The appliance must always be kept under control during use. 

 

Warning! : The manufacturer shall not be held responsible for injuries or damage due to the non-

compliance with safety rules or an improper use of the appliance by the operator.  

 

Some improper operating conditions may even be caused by an improper use of the appliance, therefore it 

is important to train personnel properly. 

 

All the installation and maintenance operations must be performed by fitters who are members of 

an official register. 

 

Respect the periods required for maintenance. With this is mind, customers are recommended to sign a 

service agreement. 

 

In case of failures concerning the appliance, all outputs (electrical power supply and water) must be cut off 

instantly. 

 

In case of recurrent failures, contact a service technician. 

 

3.2 INSTRUCTIONS 

FOR 

USE 

 

  Before cooking with the appliance for the first time, wash the interior of the cooking vat 

thoroughly. 

Warning! : 

Fill the cooking vat up to a maximum of 40 mm under the overflow border, according to 

the maximum level mark, including the food to be cooked. 
Warning! : 

Before filling the vat, always check that the drainage tap is closed. 

 

3.2.1 

FILLING THE JACKET  

 

MOD. 100-150 lt 

 

Warning! : 

The water level in the jacket must be checked each time before lighting.  

Warning! : 

It is advisable to use softened water to fill the jacket!  

 

Open the level tap on the front of the appliance. 

 

Unscrew the filling cap on the safety valve unit. The latter is on the right of the appliance surface (see 

figure “Size of appliance and position of connections ”). 

 

Fill with softened water (the capacity of the jacket is stated in the paragraph “Technical data”). 

 

When water flows out of the level tap, close it and screw back on the safety unit cap. 

 

Mod.  PM1IE200/300/500 – PMRIE100/150/200/300/500/510   –  PM9IE170/270/370GN 

 
Warning! : 

The water level in the jacket must be checked each time before lighting.  

Warning! : 

It is advisable to use softened water to fill the jacket!  

 

Open the level tap on the front of the appliance. 

Summary of Contents for PM8-9IE

Page 1: ...COD 90900110 INSTRUCTION MANUAL FOR INSTALLATION MAINTENANCE AND USE ELECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 280 019 280 020 280 021 280 022 280 023...

Page 2: ...nance of the appliance 10 2 4 1 Possible failures and their elimination 11 3 USE AND CLEANING 12 3 1 Warnings and hints for user 12 3 2 Instructions for use 12 3 2 1 Filling the jacket 12 3 2 2 Detail...

Page 3: ...detail as possible so that a service technician will be able to understand the nature of the problem Gloves should be worn to protect the hands during installation and maintenance operations Warning F...

Page 4: ...ritorial building regulations and fire prevention prescriptions current accident prevention guidelines electricity board regulations concerning safety the regulations of the electrical power supply co...

Page 5: ...113 150 Useful volume lt 102 139 Pressure cooking mod A bar 0 05 Temperature C 20 110 Jacket volume lt 32 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric power kW 16 16 18 18 Voltage Input stand...

Page 6: ...vervall volume lt 220 325 480 Useful volume lt 200 300 455 Pressure cooking mod A bar 0 05 Temperature C 20 110 Jacket volume lt 43 62 62 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric power kW...

Page 7: ...0 325 480 540 Useful volume lt 102 139 200 300 455 500 Pressure cooking mod A bar 0 05 Temperature C 20 110 Jacket volume lt 32 32 43 62 62 95 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric pow...

Page 8: ...H mm 480 Overvall volume lt 185 290 396 Useful volume lt 170 270 370 Temperature C 20 110 Jacket volume lt 44 68 90 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric power kW 24 32 36 Voltage Inp...

Page 9: ...ning Before connecting any parts of the appliance to supplies make sure that the latter is equivalent the requirements stated in the technical data plate if the appliance has been designed for these s...

Page 10: ...made in accordance with the requirements and directions indicated in this manual that all safety requirements in current standards statutory regulations and directives have been met that the water con...

Page 11: ...nate the problem causing its activation Problem and possible cause Access to components and operation The content of the vat does not heat up the safety thermostat has been activated the heating eleme...

Page 12: ...puts electrical power supply and water must be cut off instantly In case of recurrent failures contact a service technician 3 2 INSTRUCTIONS FOR USE Before cooking with the appliance for the first tim...

Page 13: ...that shows the pressure inside the cooking vat Turn off the appliance after cooking Before opening the lid release all the pressure from the cooking vat by lifting the relief valve lever see figure Co...

Page 14: ...ner addend Rinse always thoroughly and dry with a soft cloth Notes regarding the pressure kettles Do not use detergents containing high percentages of ammonia and sodium to clean the lid gasket as it...

Page 15: ...plying to a service centre unnecessarily If the problem is not solved after the necessary controls turn off the appliance immediately unplug it cut off any supplies and apply to a service centre the v...

Page 16: ...FUNCTIONS PM IE LEGEND F1 Fuse 3 15 A T S1 Jacket filling solenoid valve OPTIONAL SE Selector TS Safety thermostat L1 Green warning light TL Operating thermostat L2 Heating on signal lamp C1 Electrom...

Page 17: ...TRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 2 WIRING DIAGRAM HEATING ELEMENTS PM IE 3N PE AC 400V LEGEND mA End line terminal board C3 Electromagnetic switch security C1 Electromagnetic...

Page 18: ...TRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 3 WIRING DIAGRAM HEATING ELEMENTS PM IE 3 PE AC 230V LEGEND mA End line terminal board C3 Electromagnetic switch security C1 Electromagnetic...

Page 19: ...NDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 4 WIRING DIAGRAM HEATING ELEMENTS PM IE 3 PE AC 440V LEGEND mA End line terminal board TR Transformer 440 480 230V C1 Electromagnetic switch min R1 Heating...

Page 20: ...NDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 5 WIRING DIAGRAM HEATING ELEMENTS PM IE 3 PE AC 480V LEGEND mA End line terminal board TR Transformer 440 480 230V C1 Electromagnetic switch min R1 Heating...

Page 21: ...ELECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 6 LAYOUT CONNECTIONS PMIE LEGEND E Electrical connection 1 Cooking vat drainage tap Q Equipotential clamp 2 Vat water feed tap A Hot wate...

Page 22: ...LECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 7 LAYOUT CONNECTIONS PMRIE LEGEND E Electrical connection 1 Cooking vat drainage tap Q Equipotential clamp 2 Vat water feed tap A Hot wate...

Page 23: ...ECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 8 LAYOUT CONNECTIONS PM9IEGN LEGEND E Electrical connection 1 Cooking vat drainage tap Q Equipotential clamp 2 Vat water feed tap A Hot wat...

Page 24: ...INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 9 FIG CONTROLS LEGEND 1 Selector 4 Operating thermostat 2 Green warning light 5 Orange lamp warning light failing water in the jacket 3 Heating on signal...

Page 25: ...LATION MAINTENANCE AND USE Rev 09 PM IE 8 9 1 R GN DU GB 09 25 ELECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN OPERATING THERMOSTAT ONLY FOR PRESSURE KETTLES Valve and position of relief...

Reviews: