Possible malfunctions
16 / 20
100082
EN
7
Possible malfunctions
Mögliche
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. When malfunction cannot
be removed, contact the technical service.
Error
Possible Cause
Solution
The 'Add water'
indicator light is lit.
The water level is too low.
Add water and restart the
appliance.
The 'Ice' indicator
light is lit.
The storage container is full.
Empty the storage
container.
Both 'Add Water' and
'Ice' indicator lights
are blinking.
Ice through is stuck.
Check if the ice is blocking
the Ice through. If not,
contact the service
company.
Ice cubes stick with
one another.
The ice production cycle is
too long.
Stop the production cycle
and run it anew when
blocks of ice melt. Select a
smaller ice cube size.
The water temperature in
external tank is too low.
Exchange the water in the
water tank. Use water with
the temperature of 10 °C
–
38 °C.
The appliance is
working but is not
producing ice.
The ambient temperature or
water temperature in external
tank is too high.
The appliance should be
used in an environment
with ambient temperature
of 38 °C and with cold
water.
The coolant is escaping.
Contact the service
company.
A tube obstructed in the
cooling system.
Contact the service
company.
The appliance is
loosing water.
Maybe the closing cover is
not correctly tightened.
Tighten the closing cover.
Summary of Contents for HK150